双能CT检测疼痛性膝关节假体松动
前瞻性单中心研究纳入92例单侧疼痛性膝关节假体患者,比较双能CT、单能CT和X线摄影对假体松动的诊断效能,以手术或影像随访为参考标准。双能CT对胫骨和股骨假体松动的诊断效能总体优于单能CT或X线摄影。
要点
- 双能CT诊断胫骨假体松动的敏感度88%、特异度91%,优于单能CT和X线摄影。
- 双能CT对股骨假体松动的整体诊断效能(AUC 0.87)优于单能CT和X线摄影。
- 假体松动的诊断依据为假体周围透亮区大于2 mm。
核心结论
- 双能CT检测全膝关节置换术后胫骨和股骨假体松动的诊断效能总体优于单能CT或X线摄影。
研究设计与样本
- 所有参与者接受X线摄影、单能CT和双能CT检查,由5名盲法读者(4名放射科医生和1名骨科医生)评估图像。
- 以手术或影像随访为参考标准诊断假体松动。
诊断标准与关键数值
- 假体松动的诊断标准为假体周围透亮区大于2 mm。
- 胫骨假体松动:双能CT平均敏感度88%、特异度91%;单能CT敏感度73%、特异度78%;X线摄影敏感度68%、特异度81%。
临床应用与阅片要点
- 对于疼痛性膝关节假体患者,双能CT可作为评估假体松动的有效影像方法,尤其对胫骨和股骨假体松动的诊断优于单能CT和X线摄影。
- 阅片时应注意观察假体周围透亮区,以大于2 mm作为松动诊断标准。
局限性
- 本研究为单中心前瞻性研究,样本量有限。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Dual-energy CT (DECT) is an alternative to radiography and single-energy CT (SECT) for detecting prosthesis-related complications. Purpose To compare the diagnostic performance of DECT, SECT, and radiography for knee prosthesis loosening, with use of surgery or imaging follow-up reference standards. Materials and Methods In this prospective single-center study from December 2018 to June 2021, participants with unilateral painful knee prostheses underwent radiographic, SECT, and DECT imaging. Five blinded readers, four radiologists, and one orthopedic surgeon evaluated the images. Prosthesis loosening was diagnosed by a periprosthetic lucent zone greater than 2 mm. The sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) of each method were determined and compared with use of a multireader multicase analysis. Results There were 92 study participants (mean age ± SD, 70 years ± 9.4; 67 women) evaluated. Tibial and femoral loosening were diagnosed in 47 and 24 participants, respectively. For the tibia, mean sensitivity and specificity for arthroplasty loosening were 88% and 91%, respectively, for DECT, 73% and 78% for SECT, and 68% and 81% for radiography. For the tibia, DECT demonstrated similar diagnostic performance (AUC, 0.90) to SECT (AUC: 0.90 vs AUC: 0.87, respectively; P = .13) but was superior to radiography (AUC: 0.90 vs AUC: 0.82; P = .002). Overall diagnostic performance of DECT (AUC, 0.87) for the femur was superior to both SECT and radiography (P < .001). Conclusion Dual-energy CT had generally better diagnostic performance in detecting loosening of tibial and femoral components after total knee arthroplasty compared with single-energy CT or radiography. Clinical trial registration no. 2942 © RSNA, 2022.
引用
- Foti, Longo, D'Onofrio, et al. Dual-Energy CT for Detecting Painful Knee Prosthesis Loosening. Radiology. 2022. PMID: 36255306. doi:10.1148/radiol.211818
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。