超声脉冲长度对声学再灌注治疗的影响

Effect of Ultrasound Pulse Length on Sonoreperfusion Therapy.
PubMed 文献 · Ultrasound Med Biol · 2022-10-15

本研究在啮齿类动物后肢模型中比较长脉冲(5000周期)与短脉冲(500×10周期)超声联合微泡空化在相同声压(1.5 MPa)、频率(1 MHz)和总周期数下的再灌注效果。结果显示长脉冲引起初始血流痉挛后持续约两倍血流升高,短脉冲仅短暂升高;两种脉冲均有效恢复微血管阻塞后的血容量,但仅长脉冲增加血流速率;组织学未见损伤或出血。

要点

  • 长脉冲超声(5000周期)比短脉冲更有效恢复微血管阻塞后血流速率。
  • 长脉冲引起初始血流痉挛,4分钟自行缓解,10分钟后血流持续约两倍升高。
  • 两种脉冲均无组织损伤或出血证据,但长脉冲再灌注疗效更优。

关键影像表现/征象

  • 长脉冲导致初始血流痉挛性降低,4分钟自行缓解,10分钟后血流持续较基线升高约两倍(p < 0.05)。
  • 短脉冲引起短暂约两倍血流速率升高,峰值在4分钟(p < 0.05),无初始痉挛。
  • 长脉冲的持续血流增加并非单纯反应性充血。
  • 两种脉冲均通过恢复血容量有效再灌注微血管阻塞模型,但仅长脉冲在治疗后增加血流速率(p < 0.05)。
  • 组织学分析显示两种脉冲配置均无组织损伤或出血证据。

临床应用与阅片要点

  • 长脉冲超声可能更适用于微血管阻塞的声学再灌注治疗,需注意初始血流痉挛现象。
  • 短脉冲虽有效恢复血容量,但对血流速率的持续改善不如长脉冲。
  • 治疗中应监测血流动力学变化,初始痉挛可自行缓解,无需过度干预。

局限性

  • 研究为临床前动物模型,结果外推至人类需谨慎。
  • 样本量未在摘要中报告,可能影响统计效能。
  • 仅测试了一种频率(1 MHz)和声压(1.5 MPa),其他参数组合效果未知。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

In recent years, long- and short-pulse ultrasound (US)-targeted microbubble cavitation (UTMC) has been found to increase perfusion in healthy and ischemic skeletal muscle, in pre-clinical animal models of microvascular obstruction and in the myocardium of patients presenting with acute myocardial infarction. There is evidence that the observed microvascular vasodilation is driven by the nitric oxide pathway and purinergic signaling, but the time course of the response and the dependency on US pulse length are not well elucidated. Because our prior data supported that sonoreperfusion efficacy is enhanced by long-pulse US versus short-pulse US, in this study, we sought to compare long-pulse (5000 cycles) and short-pulse (500 × 10 cycles) US at a pressure of 1.5 MPa with an equivalent total number of acoustical cycles, hence constant acoustic energy, and at the same frequency (1 MHz), in a rodent hind limb model with and without microvascular obstruction (MVO). In quantifying perfusion using burst replenishment contrast-enhanced US imaging, we made three findings: (i) Long and short pulses result in different vasodilation kinetics in an intact hind limb model. The long pulse causes an initial spasmic reduction in flow that spontaneously resolved at 4 min, followed by sustained higher flow rates (approximately twofold) compared with baseline, starting 10 min after therapy (p < 0.05). The short pulse caused a short-lived approximately twofold increase in flow rate that peaked at 4 min (p < 0.05), but without the initial spasm. (ii) The sustained increased response with the long pulse is not simply reactive hyperemia. (iii) Both pulses are effective in reperfusion of MVO in our hindlimb model by restoring blood volume, but only the long pulse caused an increase in flow rate after treatment ii, compared with MVO (p < 0.05). Histological analysis of hind limb muscle post-UTMC with either pulse configuration indicates no evidence of tissue damage or hemorrhage. Our findings indicate that the microbubble oscillation induces vasodilation, and therapeutic efficacy for the treatment of MVO can be tuned by varying pulse length; relative to short-pulse US, longer pulses drive greater microbubble cavitation and more rapid microvascular flow rate restoration after MVO, warranting further optimization of the pulse length for sonoreperfusion therapy.