文献速递妇产影像介入MR

MRI参数预测超声引导高强度聚焦超声消融子宫肌瘤疗效

MRI parameters for predicting the effect of ultrasound-guided high-intensity focused ultrasound in the ablation of uterine fibroids.
PubMed 文献 · Clin Radiol · 2022-10-12

本研究纳入91例子宫肌瘤患者,按无灌注体积(NPV)比率和血供类型分组,分析术前MRI参数与NPV比率的相关性,并用ROC曲线确定预测消融率的界值。结果显示T2WI信号强度、T2WI肌瘤/腹直肌信号强度比及血供类型与NPV比率<80%显著相关,T2WI高信号和富血供者消融疗效较差。

要点

  • 术前MRI T2WI信号强度和血供类型可预测HIFU消融子宫肌瘤的疗效。
  • T2WI高信号、富血供的肌瘤消融效果较差。
  • T2WI信号强度与NPV比率呈负相关。

核心结论

  • MRI T2WI信号强度和血供类型是预测超声消融疗效的预测因子。
  • T2WI高信号和富血供的子宫肌瘤超声消融疗效较差。

研究设计与样本

  • 回顾性研究纳入91例子宫肌瘤患者,按NPV比率(<80%与≥80%)和血供类型分组。
  • 术前测量MRI参数,分析其与NPV比率的相关性,并用ROC曲线确定预测消融率的界值。

关键影像表现/征象

  • NPV比率<80%组与≥80%组在T2WI信号强度、T2WI肌瘤/腹直肌信号强度比和血供类型上差异有统计学意义(p<0.05)。
  • 肌瘤体积、T2WI信号均匀性和ADC值在两组间无显著差异。
  • 血供较差组的ADC值、T2WI信号强度和T2WI信号强度比均低于富血供组(p<0.05)。

诊断标准与关键数值

  • 预测NPV比率超过80%的T2WI信号强度界值为220.58。
  • 预测NPV比率超过80%的T2WI肌瘤/腹直肌信号强度比界值为1.315。

临床应用与阅片要点

  • 术前可测量子宫肌瘤T2WI信号强度及肌瘤/腹直肌信号强度比,评估HIFU消融可能疗效。
  • 关注肌瘤血供类型,富血供者提示消融效果可能不佳。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To study the value of magnetic resonance imaging (MRI) parameters in predicting the efficacy of ultrasonic ablation of fibroids.

MATERIALS AND METHODS: A total of 91 patients were divided into groups based on non-perfused volume (NPV) ratio and blood supply type. The preoperative MRI parameters were measured and analysed. A correlation analysis between the MRI parameters and the NPV ratio was performed. Receiver operating characteristic (ROC) curves were used to analyse and determine the cut-off value of MRI parameters to predict the ablation rate of fibroids.

RESULTS: The uterine fibroids group with an NPV ratio <80% and the group with an NPV ratio of ≥80% had significant differences in signal intensity (SI) at MRI T2-weighted imaging (WI), fibroid-to-rectus abdominis SI ratio (SIR) at T2WI, and blood supply type (p<0.05). There were no significant differences in fibroid volume, T2WI signal uniformity, and apparent diffusion coefficient (ADC) values. The ADC value and SI and SIR at MRI T2WI in the group with poor blood supply were lower than those in the group with a rich blood supply (p<0.05). SI at MRI T2WI correlated negatively with the NPV ratio. The cut-off values for SI and SIR at MRI T2WI of fibroids whose NPV ratio exceeds 80% were 220.58 and 1.315, respectively.

CONCLUSION: SI at MRI T2WI and blood supply type could be predictors of the efficacy of ablation. Ultrasonic ablation of fibroids with MRI T2WI hyperintensity and a rich blood supply had poor efficacy.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Liao, Xu, Bai, et al. MRI parameters for predicting the effect of ultrasound-guided high-intensity focused ultrasound in the ablation of uterine fibroids. Clin Radiol. 2022. PMID: 36241567. doi:10.1016/j.crad.2022.09.112

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。