文献速递神经儿科影像CT

全身超低剂量CT检测脑室腹腔分流管机械性并发症的诊断效能

Diagnostic Performance of Whole-Body Ultra-Low-Dose CT for Detection of Mechanical Ventriculoperitoneal Shunt Complications: A Retrospective Analysis.
PubMed 文献 · AJNR Am J Neuroradiol · 2022-10-13

本回顾性研究纳入186例患者,评估全身超低剂量CT(100 kVp,参考10 mAs)对脑室腹腔分流管机械性并发症的诊断效能。两位放射科医生阅片,结果显示敏感度和特异度均为100%,图像质量和诊断信心高,且辐射剂量显著低于传统X线分流管系列。

要点

  • 全身超低剂量CT诊断VP分流管并发症敏感度和特异度均达100%。
  • 辐射剂量(0.67 mSv)显著低于传统X线分流管系列(1.57 mSv)。
  • 图像质量和诊断信心高(中位评分5分),观察者间一致性良好。

关键影像表现/征象

  • 34例患者的VP分流管并发症被两位阅片者正确识别,无假阳性或假阴性。
  • 分流管相关图像质量和诊断信心中位评分均为5分(范围5-5)。
  • 图像质量观察者间一致性κ=0.73,诊断信心κ=0.78。

诊断标准与关键数值

  • 敏感度100%(95%CI 87.3%-100%),特异度100%(95%CI 96.9%-100%)。
  • 阳性预测值和阴性预测值均为100%。
  • 两位阅片者间完全一致(κ=1)。

临床应用与阅片要点

  • 全身超低剂量CT可作为疑似VP分流管并发症的替代影像检查,尤其适用于需低辐射剂量的患者。
  • 阅片时应关注分流管全程走行及脑室端、腹腔端位置,图像质量高可满足诊断。
  • 注意结合临床病史,避免遗漏分流管功能障碍的间接征象。

局限性

  • 回顾性研究设计。
  • 单中心研究。
  • 样本量有限(186例)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Radiographic shunt series are still the imaging technique of choice for radiologic evaluation of VP-shunt complications. Radiographic shunt series are associated with high radiation exposure and have a low diagnostic performance. Our aim was to investigate the diagnostic performance of whole-body ultra-low-dose CT for detecting mechanical ventriculoperitoneal shunt complications.

MATERIALS AND METHODS: This retrospective study included 186 patients (mean age, 54.8 years) who underwent whole-body ultra-low-dose CT (100 kV[peak]; reference, 10 mAs). Two radiologists reviewed the images for the presence of ventriculoperitoneal shunt complications, image quality, and diagnostic confidence. On a 5-point Likert scale, readers scored image quality and diagnostic confidence (1 = very low, 5 = very high). Sensitivity, specificity, positive predictive value, and negative predictive value were calculated. Radiation dose estimation of whole-body ultra-low-dose CT was calculated and compared with the radiation dose of a radiographic shunt series.

RESULTS: 34 patients positive for VP-shunt complications were correctly identified on whole-body ultra-low-dose CT by both readers. No false-positive or -negative cases were recorded by any of the readers, yielding a sensitivity of 100% (95% CI, 87.3%-100%), a specificity of 100% (95% CI, 96.9%-100%), and perfect agreement (κ = 1). Positive and negative predictive values were high at 100%. Shunt-specific image quality and diagnostic confidence were very high (median score, 5; range, 5-5). Interobserver agreement was substantial for image quality (κ = 0.73) and diagnostic confidence (κ = 0.78). The mean radiation dose of whole-body ultra-low-dose CT was significantly lower than the radiation dose of a conventional radiographic shunt series (0.67 [SD, 0.4] mSv versus 1.57 [SD, 0.6] mSv; 95% CI, 0.79-1.0 mSv; P < .001).

CONCLUSIONS: Whole-body ultra-low-dose CT allows detection of ventriculoperitoneal shunt complications with excellent diagnostic accuracy and diagnostic confidence. With concomitant radiation dose reduction on contemporary CT scanners, whole-body ultra-low-dose CT should be considered an alternative to the radiographic shunt series.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Afat, Pjontek, Nikoubashman, et al. Diagnostic Performance of Whole-Body Ultra-Low-Dose CT for Detection of Mechanical Ventriculoperitoneal Shunt Complications: A Retrospective Analysis. AJNR Am J Neuroradiol. 2022. PMID: 36229165. doi:10.3174/ajnr.A7672

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。