文献速递腹部介入MRCT

三维定量消融边缘评估在结直肠癌肝转移经皮热消融中的应用:基于半自动刚性MRI/CECT-CECT配准

Three-dimensional quantitative margin assessment in patients with colorectal liver metastases treated with percutaneous thermal ablation using semi-automatic rigid MRI/CECT-CECT co-registration.
PubMed 文献 · Eur J Radiol · 2022-10-05

本研究评估经皮热消融治疗结直肠癌肝转移(CRLM)后三维定量最小消融边缘(MAM),并分析其与局部肿瘤复发(LTR)的相关性。采用半自动刚性MRI/CECT-CECT配准软件deLIVERed对21例患者29个CRLM进行MAM定量评估,结果显示负MAM与LTR显著相关,定量MAM预测LTR的AUC达0.975±0.029,表明该技术可行且能预测局部复发。

要点

  • 定量MAM为负值时局部复发风险显著增高,负MAM患者100%出现LTR。
  • MAM每缩小1mm,LTR风险增加,AUC 0.975提示预测准确性高。
  • 配准质量不足(评分≤3)者占46%,需严格筛选病例方可应用于临床。

局限性

  • 单中心回顾性研究,样本量小(最终仅21例29个病灶)。
  • 46%患者因配准质量不足被排除,限制技术普适性。
  • 原文未报告敏感度、特异度及最佳阈值。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To assess the quantitative minimal ablation margin (MAM) in patients with colorectal liver metastases (CRLM) treated with percutaneous thermal ablation (TA) and correlate the quantitative MAM with local tumour recurrence (LTR).

METHOD: Thirty-nine of 143 patients with solitary or multiple CRLM who underwent a first percutaneous TA procedure between January 2011 and May 2020 were considered eligible for study enrolment. Image fusion of pre- and post-ablation scans and 3D quantitative MAM assessment was performed using the in-house developed semi-automatic rigid MRI/CECT-CECT co-registration software deLIVERed. The quantitative MAM was analysed and correlated with LTR.

RESULTS: Eighteen (46 %) patients were additionally excluded from further analyses due to suboptimal co-registration (quality co-registration score ≤ 3). The quality of co-registration was considered sufficient in 21 (54 %) patients with a total of 29 CRLM. LTR was found in 5 of 29 (17 %) TA-treated CRLM. In total, 12 (41 %) negative MAMs were measured (mean MAM -4.7 ± 2.7 mm). Negative MAMs were significantly more frequently seen in patients who developed LTR (100 %) compared to those without LTR (29 %; p = 0.003). The median MAM of patients who developed LTR (-6.6 mm (IQR -9.5 to -4.6)) was significantly smaller compared to the median MAM of patients without LTR (0.5 mm (IQR -1.8 to 3.0); p < 0.001). The ROC curve showed high accuracy in predicting LTR for the quantitative MAM (area under the curve of 0.975 ± 0.029).

CONCLUSION: This study demonstrated the feasibility of 3D quantitative MAM assessment, using deLIVERed co-registration software, to assess technical success of TA in patients with CRLM and to predict LTR.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Faber, Burghout, Bijlstra, et al. Three-dimensional quantitative margin assessment in patients with colorectal liver metastases treated with percutaneous thermal ablation using semi-automatic rigid MRI/CECT-CECT co-registration. Eur J Radiol. 2022. PMID: 36228455. doi:10.1016/j.ejrad.2022.110552

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。