文献速递腹部MR

移行期Gd-EOB-DTPA增强MRI:基于摄取率视觉评估肝功能和纤维化

Transitional phase Gd-EOB-DTPA-enhanced MRI: Visual assessment of hepatic function and fibrosis based on uptake rate of Gd-EOB-DTPA.
PubMed 文献 · Eur J Radiol · 2022-10-03

本研究回顾性纳入105例接受1.5T Gd-EOB-DTPA增强MRI的患者,根据移行期肝静脉与肝实质信号强度差异分为High/Iso-SI组和Low-SI组,比较两组ALBI评分、FIB-4、APRI和LSR的差异,并确定cut-off值。结果显示两组间上述指标均有显著差异,视觉评估的观察者间ICC为0.86,提示移行期视觉评估可用于肝功能和纤维化评估。

要点

  • 移行期肝静脉信号低于肝实质提示肝功能/纤维化更差。
  • 视觉评估可重复性好(ICC=0.86),适合日常阅片。
  • ALBI、FIB-4、APRI、LSR的cut-off值分别为-2.69、2.28、0.49、2.15。

关键影像表现/征象

  • 移行期肝静脉信号强度等于或高于肝实质为High and Iso-SI组,低于肝实质为Low-SI组。
  • High and Iso-SI组48例,Low-SI组57例。

诊断标准与关键数值

  • 两组间ALBI评分、FIB-4、APRI和LSR均有显著差异。
  • ALBI评分cut-off值为-2.69,FIB-4为2.28,APRI为0.49,LSR为2.15。
  • 移行期视觉评估的观察者间ICC为0.86。

临床应用与阅片要点

  • 阅片时可观察移行期肝静脉与肝实质信号强度关系,辅助判断肝功能和纤维化。
  • 注意视觉评估需结合临床和其他指标,cut-off值可供参考。

局限性

  • 回顾性研究,单中心,样本量有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The aim of the study is to investigate the feasibility for hepatic function and fibrosis visual assessment using transitional phase imaging based on the uptake process of Gd-EOB-DTPA.

MATERIALS AND METHODS: We retrospectively selected 105 consecutive patients who underwent Gd-EOB-DTPA enhanced MRI examination at 1.5 Tesla for intrahepatic lesion evaluation from June 2020 to June 2022. Data were classified into two groups defined by the signal intensity (SI) difference in the hepatic vein against that of the hepatic parenchyma at transitional phase as follows: High and Iso-SI group: hepatic vein SI equal to or greater than the hepatic parenchymal SI; and Low-SI group: hepatic vein SI lower than hepatic parenchymal SI. We evaluated whether significant differences in ALBI score, FIB-4, APRI and LSR of hepatobiliary phase between two groups. We measured cut-off values between two groups in all items according to receiver operating characteristic analysis. Furthermore, the inter-reader reproducibility of the visual assessment on transitional phase images between two readers was evaluated using the ICC.

RESULTS: The visual assessment results were as follows: High and Iso- and Low-SI groups included 48, 57, patients, respectively. Significant differences were observed in ALBI score, FIB-4, APRI and LSR between two groups. The cut-off values of ALBI score, FIB-4, APRI and LSR were -2.69, 2.28, 0.49 and 2.15. ICC of transitional phase image visual assessment between two readers was 0.86.

CONCLUSIONS: Hepatic function and fibrosis might be assessed by visual assessment of transitional phase images in Gd-EOB-DTPA enhanced MRI.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Inokuchi, Fujikawa, Uematsu, et al. Transitional phase Gd-EOB-DTPA-enhanced MRI: Visual assessment of hepatic function and fibrosis based on uptake rate of Gd-EOB-DTPA. Eur J Radiol. 2022. PMID: 36223667. doi:10.1016/j.ejrad.2022.110550

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。