多参数MRI在鉴别子宫平滑肌肉瘤与良性退变性平滑肌瘤及变异型中的作用:回顾性分析
结果显示浸润性边缘仅见于平滑肌肉瘤,T2W高信号<25%仅见于良性退变性平滑肌瘤,坏死合并出血仅见于平滑肌肉瘤;定量MRI参数在三组间无显著差异。结论认为三者在多参数MRI上表现重叠,鉴别困难。
要点
- 浸润性边缘仅见于平滑肌肉瘤,但多数平滑肌肉瘤仍呈分叶或光滑边缘,与良性病变重叠。
- T2W高信号<25%仅见于良性退变性平滑肌瘤,可提示良性退变。
- 坏死合并出血仅见于平滑肌肉瘤,出现时需警惕恶性。
局限性
- 回顾性分析,样本量小(共27例,其中平滑肌肉瘤仅5例),结论需更大样本验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
AIM: To assess qualitative and quantitative magnetic resonance imaging (MRI) factors that can help distinguish leiomyosarcoma (LMS) from benign degenerative leiomyoma (BDL) and leiomyoma variants (LV) and assess the interobserver agreement for the proposed quantitative factors.
MATERIALS AND METHODS: Retrospective analysis of all histopathology proven cases of LV, BDL, and LMS with a preoperative MRI was performed. Twenty-seven cases were included (five LMS, three LV, and 19 BDL) with each case independently read by a pair of radiologists. Lesion size, margins, presence or absence of degeneration, necrosis, and haemorrhage were assessed on MRI along with quantitative factors such as mean T2-weighted (W) and T1W signal intensity, T1W signal heterogeneity, diffusion-weighted imaging (DWI), and apparent diffusion coefficient (ADC) ratios as well as dynamic contrast enhancement (DCE) characteristics along with the presence or absence of lymphadenopathy and extra-uterine and peritoneal spread. Mean and standard deviation for quantitative variables and frequency with percentages for qualitative variables were assessed.
RESULTS: Infiltrative margins were seen exclusively in the LMS group (n=1), with the remaining LMS cases showing lobulate or rounded smooth margins similar to BDL or LV. A high T2W signal <25% was seen exclusively in the BDL group (n=8). The presence of concomitant necrosis and haemorrhage was seen exclusively in the LMS group (n=2). Quantitative MRI had good inter-reader correlation but was not significantly different between the LMS, BDL, and LV groups.
CONCLUSION: LMS, BDL, and LV may have overlapping features on multiparametric MRI making differentiation difficult.
引用
- Mahmood, Al Rashid, Ladumor, et al. The role of multiparametric MRI in differentiating uterine leiomyosarcoma from benign degenerative leiomyoma and leiomyoma variants: a retrospective analysis. Clin Radiol. 2022. PMID: 36220736. doi:10.1016/j.crad.2022.08.144
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。