快门速度DCE-MRI水交换参数鉴别胶质母细胞瘤与单发脑转移瘤
本研究纳入40例胶质母细胞瘤和48例单发脑转移瘤患者,术前进行快门速度DCE-MRI,计算瘤周区和强化肿瘤区的血管内水流出速率常数kbo和细胞内水流出速率常数kio。结果显示两组间kbo在瘤周区和强化区均有统计学差异,免疫组化提示GBM血管周围aquaporin-4高表达可能解释其较高的kbo值。结论认为kbo是区分GBM与SBM的独立病理生理参数。
要点
- kbo在瘤周区和强化肿瘤区均可区分GBM与SBM
- GBM的kbo值高于SBM,可能与血管周围aquaporin-4高表达有关
- BSS DCE-MRI水交换参数可作为术前无创鉴别指标
核心结论
- BSS DCE-MRI衍生的kbo是区分胶质母细胞瘤与单发脑转移瘤的独立病理生理参数。
- kbo可能反映血管周围aquaporin-4表达水平。
研究设计与样本
- 前瞻性观察性研究,纳入40例GBM和48例SBM患者,术前行BSS DCE-MRI,以免疫组化aquaporin-4染色验证机制。
关键影像表现/征象
- 瘤周区kbo在SBM与GBM分别为1.0[0.4,1.7] s-1和1.5[0.9,2.1] s-1,差异有统计学意义(p=0.009)。
- 强化肿瘤区kbo在SBM与GBM分别为0.2[0.1,0.5] s-1和0.4[0.1,1.3] s-1,差异有统计学意义(p=0.034)。
- 免疫组化显示GBM血管周围aquaporin-4高表达,可能解释其较高kbo值。
临床应用与阅片要点
- 在术前MRI鉴别GBM与SBM时,可关注BSS DCE-MRI计算的kbo值,GBM倾向于更高。
- 瘤周区和强化肿瘤区的kbo均有鉴别价值,但需结合常规影像特征综合判断。
局限性
- 样本量有限(GBM 40例,SBM 48例),为单中心观察性研究。
- 未报告敏感度、特异度、AUC或诊断阈值,临床 cutoff 值尚待确定。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: This study aimed to explore the feasibility of transmembrane water exchange parameters detected by brain shutter speed (BSS) dynamic contrast enhanced (DCE)MRI, which is validated to be associated with aquaporin-4 expression, in distinguishing glioblastoma (GBM) from solitary brain metastasis (SBM).
METHODS: 40 patients (mean age: 58.6 ± 11.7 years old, male/female: 23/17) with GBM and 48 patients (mean age: 61.7 ± 10.5 years old, male/female: 28/20) with SBM were enrolled in this observational study. BSS DCE-MRI was performed before operation. Intravascular water efflux rate constant (kbo) and intracellular water efflux rate constant (kio) within the peritumoral region and enhancing tumor were calculated from SS-DCE, respectively. The difference of these two parameters between GBM and SBM was explored. Immunohistochemical staining aquaporin-4 of was performed to validate its underlying biological mechanism.
RESULTS: The kbo was found to be statistically different within both peritumoral region {SBM vs. GBM (s-1): 1.0[0.4,1.7] vs. 1.5[0.9,2.1], p = 0.009} and enhanced tumor {SBM vs. GBM (s-1): 0.2[0.1,0.5] vs. 0.4[0.1,1.3], p = 0.034}. Immunohistochemical analysis reveals the high perivascular aquaporin-4 expression in GBM may contribute the higher kbo value than that of SBM.
CONCLUSIONS: kbo derived from BSS DCE-MRI was an independent pathophysiological parameter for separating GBM from SBM, in which kbo might be associated with the perivascular aquaporin-4 expression.
引用
- Wang, Wang, Jia, et al. Water exchange detected by shutter speed dynamic contrast enhanced-MRI help distinguish solitary brain metastasis from glioblastoma. Eur J Radiol. 2022. PMID: 36219917. doi:10.1016/j.ejrad.2022.110526