文献速递泌尿生殖MR

CAD生成的MRI序列提升前列腺癌检出:多阅片者多病例研究

Improving Prostate Cancer Detection With MRI: A Multi-Reader, Multi-Case Study Using Computer-Aided Detection (CAD).
PubMed 文献 · Acad Radiol · 2022-10-07

九名放射科医生回顾性解读150例前列腺MRI,先无CAD后有CAD生成的随机森林模型MRI序列,以活检Gleason≥7为参考。加入CAD后,PI-RADS评分阅片者间一致性从中等提升至显著(IRA 0.47 vs 0.65,P<.001),平均AUC从0.67升至0.72(P=.02),移行带获益尤为明显。

要点

  • CAD生成的MRI序列可提高前列腺临床显著癌的检出AUC(0.72 vs 0.67)。
  • 加入CAD后PI-RADS评分阅片者间一致性由中等升至显著(IRA 0.47 vs 0.65)。
  • 移行带亚组获益更明显,阅片时可重点关注移行带病灶。

核心结论

  • 基于随机森林方法的CAD生成MRI图像序列可改善临床显著前列腺癌检出的阅片者间一致性和诊断性能,尤其在移行带。

研究设计与样本

  • 回顾性多阅片者多病例研究,9名放射科医生解读150例前列腺MRI,无CAD与有CAD序列自身对照,参考标准为活检Gleason≥7腺癌。
  • 使用随机森林基于的CAD模型生成额外MRI序列,采用MRMC方法估计AUC,加权一致性统计评估阅片者间一致性,并重复分析外周带和移行带亚组。

关键影像表现/征象

  • 临床显著前列腺癌组年龄更大(68±7.6岁 vs 66±7.0岁,p<.02),前列腺体积更小(43.9 mL vs 60.6 mL,p<.001),PSA密度更高(0.17 ng/mL/cc vs 0.10 ng/mL/cc,p<.001),PSA水平无差异(7.8 ng/mL vs 6.9 ng/mL,p=.08)。

诊断标准与关键数值

  • 有CAD序列时平均阅片者AUC=0.72,无CAD时AUC=0.67(p=.02)。
  • PI-RADS评分阅片者间一致性无CAD为IRA=0.47,有CAD为IRA=0.65(p<.001)。

临床应用与阅片要点

  • 日常阅片可考虑联合CAD生成序列辅助前列腺MRI评估,尤其在移行带。
  • CAD改善一致性提示有助于减少不同阅片者间的PI-RADS评分变异。

局限性

  • 回顾性研究设计,样本量150例,单一CAD模型,需外部验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

RATIONALE AND OBJECTIVES: To evaluate whether addition of a computer-aided diagnostic (CAD) generated MRI series improves detection of clinically significant prostate cancer.

MATERIALS AND METHODS: Nine radiologists retrospectively interpreted 150 prostate MRI examinations without and then with an additional random forest-based CAD model-generated MRI series. Characteristics of biopsy negative versus positive (Gleason ≥ 7 adenocarcinoma) groups were compared using the Wilcoxon test for continuous and Pearson's chi-squared test for categorical variables. The diagnostic performance of readers was compared without versus with CAD using MRMC methods to estimate the area under the receiver operator characteristic curve (AUC). Inter-reader agreement was assessed using weighted inter-rater agreement statistics. Analyses were repeated in peripheral and transition zone subgroups.

RESULTS: Among 150 men with median age 67 ± 7.4 years, those with clinically significant prostate cancer were older (68 ± 7.6 years vs. 66 ± 7.0 years; p < .02), had smaller prostate volume (43.9 mL vs. 60.6 mL; p < .001), and no difference in prostate specific antigen (PSA) levels (7.8 ng/mL vs. 6.9 ng/mL; p = .08), but higher PSA density (0.17 ng/mL/cc vs. 0.10 ng/mL/cc; p < .001). Inter-rater agreement (IRA) for PI-RADS scores was moderate without CAD and significantly improved to substantial with CAD (IRA = 0.47 vs. 0.65; p < .001). CAD also significantly improved average reader AUC (AUC = 0.72, vs. AUC = 0.67; p = .02).

CONCLUSION: Addition of a random forest method-based, CAD-generated MRI image series improved inter-reader agreement and diagnostic performance for detection of clinically significant prostate cancer, particularly in the transition zone.

来源:Acad Radiol,查看原文。版权归原作者所有。

引用

  1. Anderson, Mercaldo, Chung, et al. Improving Prostate Cancer Detection With MRI: A Multi-Reader, Multi-Case Study Using Computer-Aided Detection (CAD). Acad Radiol. 2022. PMID: 36216684. doi:10.1016/j.acra.2022.09.009

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。