文献速递外周血管神经CT

光谱光子计数CT评估颈动脉斑块成分与组织病理学对照

Components of carotid atherosclerotic plaque in spectral photon-counting CT with histopathologic comparison.
PubMed 文献 · Eur Radiol · 2022-10-07

本研究为单中心离体横断面观察性研究,对20例颈动脉内膜切除标本行光谱光子计数CT扫描,量化纤维帽厚度、纤维帽面积和脂质rich坏死核心面积,并与组织病理学对照。结果显示纤维帽厚度和面积无显著差异,脂质rich坏死核心面积在读者1中无显著差异,Bland-Altman分析显示一致性良好。结论认为SPCCT可定量颈动脉斑块成分。

要点

  • SPCCT可定量离体颈动脉斑块的纤维帽厚度、面积及脂质rich坏死核心面积。
  • SPCCT测量与组织病理学测量无显著差异,一致性良好。
  • 高空间分辨率和能量分辨率是准确量化斑块成分的关键。

诊断标准与关键数值

  • 纤维帽厚度SPCCT与病理学测量p值范围0.15-0.51,无显著差异。
  • 纤维帽面积p值范围0.053-0.30,无显著差异。
  • 脂质rich坏死核心面积读者1p值范围0.36-0.81,无显著差异。
  • Bland-Altman分析显示纤维帽厚度平均差及95%CI为0.04(-0.36至0.12)sqrt mm,纤维帽面积为-0.18(-0.34至-0.02)log10 mm²,脂质rich坏死核心面积为0.10(-0.088至0.009)log10 mm²。

局限性

  • 离体研究,样本量较小(20例),单中心设计。
  • 脂质rich坏死核心面积仅在读者1中无显著差异,读者间一致性需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: This study aimed to demonstrate the effectiveness of spectral photon-counting CT (SPCCT) in quantifying fibrous cap (FC) thickness, FC area, and lipid-rich necrotic core (LRNC) area, in excised carotid atherosclerotic plaques by comparing it with histopathological measurements.

METHODS: This is a single-center ex vivo cross-sectional observational study. Excised plaques of 20 patients (71 +/- 6 years; 13 men), obtained from carotid endarterectomy were scanned with SPCCT using standardized acquisition settings (120k Vp/19 μA; 7-18 keV, 18-30 keV, 30-45 keV, 45-75 keV, and 75-118 keV). FC thickness, FC area, and LRNC area were quantified and compared between high-resolution 3D multi-energy CT images and histopathology using the Wilcoxon signed-ranks test and Bland-Altman analysis. Images were interpreted twice by two radiologists separately, blinded to the histopathology; inter- and intra-rater reliability were assessed with the intra-class correlation coefficients (ICC).

RESULTS: FC thickness and FC area did not show significant differences between the SPCCT-derived radiological measurements versus the histopathological measurements (p value range 0.15-0.51 for FC thickness and 0.053-0.30 for FC area). For the LRNC area, the p value was statistically non-significant for reader 1 (range 0.36-0.81). The Bland-Altman analysis showed mean difference and 95% confidence interval for FC thickness, FC area, and LRNC area, 0.04 (-0.36 to 0.12) square root mm, -0.18 (-0.34 to -0.02) log10 mm2 and 0.10 (-0.088. to 0.009) log10 mm2 respectively.

CONCLUSION: The result demonstrated a viable technique for quantifying FC thickness, FC area, and LRNC area due to the combined effect of high spatial and energy resolution of SPCCT.

KEY POINTS: • SPCCT can identify and quantify different components of carotid atherosclerotic plaque in ex vivo study. • Components of atherosclerotic plaque did not show significant differences between the SPCCT-derived radiological measurements versus the histopathological measurements.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Dahal, Raja, Searle, et al. Components of carotid atherosclerotic plaque in spectral photon-counting CT with histopathologic comparison. Eur Radiol. 2022. PMID: 36205768. doi:10.1007/s00330-022-09155-x

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。