文献速递神经介入CTDSA

全脑时间分辨平板探测器成像衍生侧支循环评分与急性缺血性卒中DSA评分的相关性

Correlation of Collateral Scores Derived from Whole-Brain Time-Resolved Flat Panel Detector Imaging in Acute Ischemic Stroke.
PubMed 文献 · AJNR Am J Neuroradiol · 2022-10-06

结果显示多期CTA评分与DSA评分强相关,灌注不足强度比与多期CTA评分强相关,与DSA评分中等相关;梗死核心体积与多期CTA评分及灌注不足强度比强相关。结论认为平板探测器CT衍生的侧支评分在临床上是可靠的。

要点

  • 多期平板探测器CTA的Calgary/Menon评分与DSA的ASITN/SIR评分强相关(ρ=0.54,P=.002)。
  • 灌注不足强度比与多期CTA评分强相关(ρ=-0.57,P<.001),与DSA评分中等相关(ρ=-0.49,P=.006)。
  • 梗死核心体积与多期CTA评分(ρ=-0.66)及灌注不足强度比(ρ=0.76)强相关。

核心结论

  • 平板探测器CT多期CTA的Calgary/Menon评分和灌注不足强度比与DSA的ASITN/SIR评分(金标准)相关。
  • 在本队列中,平板探测器CT衍生的侧支评分在临床上是可靠的。

研究设计与样本

  • 从平板探测器CTP计算灌注不足强度比,定义为time-to-maximum > 10秒体积/time-to-maximum > 6秒体积。
  • 以DSA的ASITN/SIR侧支评分为金标准,比较多期平板探测器CTA的Calgary/Menon评分及灌注不足强度比。
  • 采用组内相关系数评估评分者间信度,采用Spearman相关分析各评分间的相关性。

诊断标准与关键数值

  • ASITN/SIR DSA评分的评分者间信度中等:组内相关系数0.68(95% CI,0.50-0.82)。
  • Calgary/Menon多期平板探测器CTA评分的评分者间信度中等:组内相关系数0.53(95% CI,0.29-0.72)。
  • ASITN/SIR DSA评分与Calgary/Menon多期CTA评分强相关:ρ=0.54,P=.002。
  • 灌注不足强度比与Calgary/Menon多期CTA评分强相关:ρ=-0.57,P<.001;与ASITN/SIR DSA评分中等相关:ρ=-0.49,P=.006。
  • 梗死核心体积与Calgary/Menon多期CTA评分强相关(ρ=-0.66,P<.001),与灌注不足强度比强相关(ρ=0.76,P<.001),与ASITN/SIR DSA评分中等相关(ρ=-0.46,P=.01)。

临床应用与阅片要点

  • 在血管内治疗前,可利用平板探测器CT多期CTA的Calgary/Menon评分快速评估侧支循环,并与DSA的ASITN/SIR评分相互参照。
  • 灌注不足强度比可作为侧支循环状态的补充指标,其与多期CTA评分和梗死核心体积相关性较好。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: Flat panel detector CT imaging allows simultaneous acquisition of multiphase flat panel CTA and flat panel CTP imaging directly in the angio suite. We compared collateral assessment derived from multiphase flat panel CTA and flat panel CTP with collateral assessment derived from DSA as the gold-standard.

MATERIALS AND METHODS: We performed a retrospective analysis of patients with occlusion of the first or second segment of the MCA who underwent pre-interventional flat panel detector CT. The hypoperfusion intensity ratio as a correlate of collateral status was calculated from flat panel CTP (time-to-maximum > 10 seconds volume/time-to-maximum > 6 seconds volume). Intraclass correlation coefficients were calculated for interrater reliability for the Calgary/Menon score for multiphase flat panel CTA and for the American Society of Interventional and Therapeutic Neuroradiology/Society of Interventional Radiology (ASITN/SIR) score for DSA collateral scores. Correlations of the hypoperfusion intensity ratio, multiphase flat panel CTA score, and the ASITN/SIR score were calculated using the Spearman correlation.

RESULTS: From November 2019 to February 2020, thirty patients were included. Moderate interrater reliability was achieved for the ASITN/SIR DSA score (0.68; 95% CI, 0.50-0.82) as well as for the Calgary/Menon multiphase flat panel CTA score (0.53; 95% CI, 0.29-0.72). We found a strong correlation between the ASITN/SIR DSA and Calgary/Menon multiphase flat panel CTA score (ρ = 0.54, P = .002) and between the hypoperfusion intensity ratio and the Calgary/Menon multiphase flat panel CTA score (ρ = -0.57, P < .001). The correlation was moderate between the hypoperfusion intensity ratio and the ASITN/SIR DSA score (ρ = -0.49, P = .006). The infarct core volume correlated strongly with the Calgary/Menon multiphase flat panel CTA score (ρ = -0.66, P < .001) and the hypoperfusion intensity ratio (ρ = 0.76, P < .001) and correlated moderately with the ASITN/SIR DSA score (ρ = -0.46, P = .01).

CONCLUSIONS: The Calgary/Menon multiphase flat panel CTA score and the hypoperfusion intensity ratio correlated with each other and with the ASITN/SIR DSA score as the gold-standard. In our cohort, the collateral scoring derived from flat panel detector CT was clinically reliable.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Kurmann, Kaesmacher, Pilgram-Pastor, et al. Correlation of Collateral Scores Derived from Whole-Brain Time-Resolved Flat Panel Detector Imaging in Acute Ischemic Stroke. AJNR Am J Neuroradiol. 2022. PMID: 36202551. doi:10.3174/ajnr.A7657

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。