深度学习图像重建算法在双能CT中降低图像噪声但改变影像组学特征:一项体模研究

Deep learning image reconstruction algorithm reduces image noise while alters radiomics features in dual-energy CT in comparison with conventional iterative reconstruction algorithms: a phantom study.
PubMed 文献 · Eur Radiol · 2022-10-05

该体模研究比较了深度学习图像重建(DLIR)与传统迭代重建(IR)在双能CT(DECT)中的图像质量和影像组学稳健性。DLIR显著改善图像质量,但与传统IR相比,重建算法间的影像组学特征可重复性较低;在多次扫描间,93.87%的特征可重复,但仅9个特征在重建算法和扫描仪间均稳健。

要点

  • DLIR可显著降低DECT图像噪声并提高信噪比和对比噪声比。
  • DLIR与传统IR之间的影像组学特征可重复性较低,可能影响特征稳定性。
  • 仅有9个影像组学特征在重复扫描和不同重建算法/扫描仪间均稳健。

关键影像表现/征象

  • DLIR显著改善图像质量,表现为最高的噪声降低率和最低的峰值频率偏移。
  • 重复扫描间93.87%的特征可重复。

诊断标准与关键数值

  • ASIR-V图像与其他传统IR的重建算法间可重复性高于DLIR(ICC均值0.603 vs 0.558,p=0.001;CCC均值0.554 vs 0.510,p=0.004)。
  • 按CV和QCD评估,扫描仪间可重复的特征分别占7.45%和26.83%。
  • 稳健特征定义为通过重复性和可重复性分析的特征,共9个。

临床应用与阅片要点

  • 在日常阅片中,DLIR可提供更高质量的DECT图像,但需注意其可能改变影像组学特征,影响基于特征的定量分析。
  • 若进行影像组学研究,应优先选择在重建算法和扫描仪间均稳健的9个特征,并注意重建算法对特征稳定性的影响。

局限性

  • 体模研究,未在临床患者中验证。
  • 仅在一台DECT扫描仪上比较了DLIR与传统IR,其他扫描仪仅使用传统IR。
  • 未评估所有可能的DLIR设置或临床相关因素。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVES: To compare image quality between a deep learning image reconstruction (DLIR) algorithm and conventional iterative reconstruction (IR) algorithms in dual-energy CT (DECT) and to assess the impact of these algorithms on radiomics robustness.

METHODS: A phantom with clinical-relevant densities was imaged on seven DECT scanners with the same voxel size using typical abdominal-pelvis examination protocols. On one DECT scanner, raw data were reconstructed using both conventional IR (adaptive statistical iterative reconstruction-V, ASIR-V) and DLIR. Nine sets of corresponding images were generated on other six DECT scanners using scanner-equipped conventional IR. Regions of interest were delineated through rigid registrations. Image quality was compared. Pyradiomics platform was used for radiomics feature extraction. Test-retest repeatability was assessed by Bland-Altman analysis for repeated scans. Inter-reconstruction algorithm reproducibility between conventional IR and DLIR was tested by intraclass correlation coefficient (ICC) and concordance correlation coefficient (CCC). Inter-scanner reproducibility was evaluated by coefficient of variation (CV) and quartile coefficient of dispersion (QCD). Robust features were identified.

RESULTS: DLIR significantly improved image quality. Ninety-four radiomics features were extracted and nine features were considered as robust. 93.87% features were repeatable between repeated scans. ASIR-V images showed higher reproducibility to other conventional IR than DLIR (ICC mean, 0.603 vs 0.558, p = 0.001; CCC mean, 0.554 vs 0.510, p = 0.004). 7.45% and 26.83% features were reproducible among scanners evaluated by CV and QCD, respectively.

CONCLUSIONS: DLIR improves quality of DECT images but may alter radiomics features compared to conventional IR. Nine robust DECT radiomics features were identified.

KEY POINTS: • DLIR improves DECT image quality in terms of signal-to-noise ratio and contrast-to-noise ratio compared with ASIR-V and showed the highest noise reduction rate and lowest peak frequency shift. • Most of radiomics features are repeatable between repeated DECT scans, while inter-reconstruction algorithm reproducibility between conventional IR and DLIR, and inter-scanner reproducibility, are low. • Although DLIR may alter radiomics features compared to IR algorithms, nine radiomics features survived repeatability and reproducibility analysis among DECT scanners and reconstruction algorithms, which allows further validation and clinical-relevant analysis.

来源:Eur Radiol,查看原文。版权归原作者所有。

引用

  1. Zhong, Xia, Chen, et al. Deep learning image reconstruction algorithm reduces image noise while alters radiomics features in dual-energy CT in comparison with conventional iterative reconstruction algorithms: a phantom study. Eur Radiol. 2022. PMID: 36197579. doi:10.1007/s00330-022-09119-1

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。