深度学习重建在冠状动脉CT血管成像中提升图像质量及支架与瓣膜结构可见性

Improvement in Image Quality and Visibility of Coronary Arteries, Stents, and Valve Structures on CT Angiography by Deep Learning Reconstruction.
PubMed 文献 · Korean J Radiol · 2022-09-29

研究纳入51例患者,对比DLR、FBP和混合迭代重建的CCTA图像质量与支架评估。DLR噪声显著更低、SNR/CNR更高、支架边缘上升斜率更高且距离更短,主观评分更优。结论认为DLR重建图像优于FBP和混合迭代重建。

要点

  • DLR显著降低图像噪声并提高SNR和CNR,利于冠状动脉及支架细节显示。
  • DLR提高支架边缘上升斜率并缩短边缘上升距离,改善支架显示锐利度。
  • DLR对主动脉瓣及三尖瓣装置(瓣环、瓣叶、乳头肌、腱索)主观显示评分更高。

核心结论

  • DLR重建在CCTA中较FBP和混合迭代重建提供更优图像质量,并改善支架和瓣膜结构的可见性。

研究设计与样本

  • 单中心研究,纳入51例患者(平均年龄63.9±9.8岁,男性36例),对CCTA图像分别行DLR、FBP和混合迭代重建并定量与主观评估。
  • 定量指标包括CT衰减值、图像噪声、SNR、CNR及支架的10%-90%边缘上升斜率和边缘上升距离,主观评分采用5分制(1最差至5最佳)。

关键影像表现/征象

  • DLR在主动脉内提供更高HU值,而在脂肪和肌肉中衰减与FBP及混合迭代重建相似。
  • 支架边缘上升斜率均值DLR为1260.4±242.5 HU/mm,高于FBP的801.9±170.7 HU/mm和混合迭代重建的641.9±112.0 HU/mm。
  • 支架边缘上升距离DLR为0.8±0.1 mm,FBP和混合迭代重建均为1.1±0.2 mm。

诊断标准与关键数值

  • 图像噪声(HU)DLR为12.6±2.2,显著低于混合迭代重建的24.2±3.0和FBP的54.2±9.5(p<0.001)。
  • SNR和CNR在DLR组显著高于FBP和混合迭代重建组(p<0.001)。
  • 主观视觉评分DLR高于FBP和混合迭代重建图像,评分项目包括整体图像质量、图像噪声以及支架、血管和主动脉瓣及三尖瓣装置显示。

临床应用与阅片要点

  • 在CCTA支架评估和瓣膜结构显示中,可优先考虑DLR重建以降低噪声、提升边缘锐利度和主观可读性。
  • 报告时可结合DLR的定量噪声及SNR/CNR优势,但需注意其主动脉HU值较FBP和混合迭代重建更高。

局限性

  • 单中心研究,样本量51例,未报告多中心验证或不同扫描设备间的可重复性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: This study aimed to investigate whether a deep learning reconstruction (DLR) method improves the image quality, stent evaluation, and visibility of the valve apparatus in coronary computed tomography angiography (CCTA) when compared with filtered back projection (FBP) and hybrid iterative reconstruction (IR) methods.

MATERIALS AND METHODS: CCTA images of 51 patients (mean age ± standard deviation [SD], 63.9 ± 9.8 years, 36 male) who underwent examination at a single institution were reconstructed using DLR, FBP, and hybrid IR methods and reviewed. CT attenuation, image noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and stent evaluation, including 10%-90% edge rise slope (ERS) and 10%-90% edge rise distance (ERD), were measured. Quantitative data are summarized as the mean ± SD. The subjective visual scores (1 for worst -5 for best) of the images were obtained for the following: overall image quality, image noise, and appearance of stent, vessel, and aortic and tricuspid valve apparatus (annulus, leaflets, papillary muscles, and chordae tendineae). These parameters were compared between the DLR, FBP, and hybrid IR methods.

RESULTS: DLR provided higher Hounsfield unit (HU) values in the aorta and similar attenuation in the fat and muscle compared with FBP and hybrid IR. The image noise in HU was significantly lower in DLR (12.6 ± 2.2) than in hybrid IR (24.2 ± 3.0) and FBP (54.2 ± 9.5) (p < 0.001). The SNR and CNR were significantly higher in the DLR group than in the FBP and hybrid IR groups (p < 0.001). In the coronary stent, the mean value of ERS was significantly higher in DLR (1260.4 ± 242.5 HU/mm) than that of FBP (801.9 ± 170.7 HU/mm) and hybrid IR (641.9 ± 112.0 HU/mm). The mean value of ERD was measured as 0.8 ± 0.1 mm for DLR while it was 1.1 ± 0.2 mm for FBP and 1.1 ± 0.2 mm for hybrid IR. The subjective visual scores were higher in the DLR than in the images reconstructed with FBP and hybrid IR.

CONCLUSION: DLR reconstruction provided better images than FBP and hybrid IR reconstruction.

来源:Korean J Radiol,查看原文。版权归原作者所有。