彩色多普勒超声测量输尿管喷尿角诊断儿童膀胱输尿管反流
前瞻性队列纳入122例疑似VUR患儿共238个肾单位,均行超声与VCUG检查,反流组喷尿角均值60.47°显著高于非反流组42.59°(P<.001)。以50°为界诊断反流的敏感度70%、特异度79%;≥68°诊断IV/V级反流敏感度70%、特异度84%。
要点
- 彩色多普勒测量输尿管喷尿角可作为儿童VUR的无创筛查工具。
- 喷尿角≥50°提示反流,≥68°提示高级别(IV/V级)反流。
- 反流分级越高喷尿角越大,但5级反而不升高。
核心结论
- 彩色多普勒超声测量输尿管喷尿角诊断VUR准确性较高,可作为儿童VUR的替代初筛或随访工具。
研究设计与样本
- 前瞻性队列研究,纳入2019–2021年单中心122例疑似VUR的儿科患者、共238个肾单位,均行超声及VCUG检查,以VCUG为参考标准。
关键影像表现/征象
- 反流肾单位输尿管喷尿角均值为60.47±16.66度,非反流肾单位为42.59±13.26度,两组差异显著(P<.001)。
- 反流0至5级(除1级外)的喷尿角均值分别为42.59、45.89、60.32、68.23和56.16度,除5级外各反流级别间角度值显著升高。
诊断标准与关键数值
- 以喷尿角50度为界诊断反流(I–V级),敏感度70%、特异度79%。
- 以喷尿角≥68度为界诊断IV/V级反流,敏感度70%、特异度84%。
临床应用与阅片要点
- 在疑似VUR患儿的超声检查中可加用彩色多普勒测量输尿管喷尿角,辅助判断反流风险。
- 喷尿角≥50度提示反流可能,≥68度提示高级别反流,可据此建议进一步VCUG或随访。
局限性
- 单中心前瞻性研究,样本来自特定时间段就诊的可疑VUR患儿,结论外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: This study hypothesizes using color Doppler ultrasound to measure ureteral jet angles (UJA) as a diagnostic screening tool for reflux.
METHODS: The present prospective cohort study included 122 patients and 238 renal unit pediatric patients suspected of VUR who presented to our hospital between 2019 and 2021. All patients underwent ultrasonography and VCUG, and the UJA was measured color Doppler evaluation of the ureteral jet. The UJA was compared with the VCUG findings in patients with and without reflux. SPSS 26 was used to analyze the data.
RESULTS: A total of 96 patients and 139 renal units exhibited reflux. The mean ureteral jet angle in refluxing units was 60.47 + 16.66 degrees, whereas, it was 42.59 + 13.26 degrees in non-refluxing units, a significant difference between the two groups (P < .001). The mean ureteral jet angle was 42.59, 45.89, 60.32, 68.23, and 56.16, for reflux grading from 0 to 5 (except grade 1), respectively. The angle value in each reflux grade increased significantly except for grade 5. For reflux detection (grade I-V), a cut-off angle of 50 degrees was associated with sensitivity and specificity of 70 and 79, respectively. Grade IV/V reflux can be diagnosed with a sensitivity of 70% and specificity of 84% using a cut-off angle of 68 degrees or greater.
CONCLUSIONS: UJA detection via color Doppler ultrasound demonstrates high accuracy, is non-invasive method can be utilized as an alternative primary diagnostic tool or in follow-up cases of VUR in children.
引用
- Zadeh, Sadeghi-Bojd, Ansari-Moghaddam, et al. Color Doppler Ultrasound's Utility in Detecting Vesicoureteral Reflux Using the Ureteral Jet Angle. J Ultrasound Med. 2022. PMID: 36190168. doi:10.1002/jum.16107
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。