胎儿贫血时心脏流入道特征:基于孕中期血红蛋白Bart病的研究
这项前瞻性研究纳入428例孕17-22周有血红蛋白Bart病风险的胎儿,在诊断性脐带穿刺前进行超声心动图检查,分析流入道指标(充盈时间分数FTF和E/A比值)。88例(20.6%)受累胎儿双侧FTF显著降低、双侧E/A比值显著升高;右侧FTF预测受累胎儿的AUC为0.707,略优于左侧(0.680),三尖瓣E/A比值略优于二尖瓣,且FTF优于E/A比值。流入道参数可能作为胎儿贫血的新预测指标,尤其在高风险妊娠中。
要点
- 孕中期血红蛋白Bart病受累胎儿双侧心室FTF显著降低,提示存在一定程度的舒张性心室功能障碍。
- 受累胎儿双侧房室瓣E/A比值显著升高,提示容量负荷增加。
- 右侧FTF预测受累胎儿的AUC为0.707,略优于左侧FTF(AUC 0.680),且FTF预测性能优于E/A比值。
关键影像表现/征象
- 受累胎儿双侧FTF显著低于未受累胎儿。
- 受累胎儿双侧E/A比值显著高于未受累胎儿。
- 右侧FTF预测受累胎儿的AUC为0.707,左侧FTF的AUC为0.680,差异有统计学意义(P < .001)。
- 三尖瓣E/A比值预测性能略优于二尖瓣E/A比值。
- FTF预测受累胎儿的性能优于E/A比值。
诊断标准与关键数值
- 受累胎儿88例(20.6%),诊断时平均孕周19.43 ± 1.5周。
- 右侧FTF预测受累胎儿的AUC为0.707,左侧FTF的AUC为0.680(P < .001)。
临床应用与阅片要点
- 对于有血红蛋白Bart病风险的胎儿,可在孕中期超声心动图检查中测量双侧流入道FTF和E/A比值。
- 右侧FTF和三尖瓣E/A比值预测性能略优,阅片时可优先关注右侧流入道指标。
- FTF降低和E/A比值升高提示胎儿贫血可能,需结合临床和脐带穿刺结果综合判断。
局限性
- 研究仅纳入孕17-22周有血红蛋白Bart病风险的胎儿,结论外推需谨慎。
- 采用离线盲法测量,但未报告测量者间一致性。
- 未报告敏感度、特异度及最佳阈值。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To identify the inflow (filling time fraction [FTF] and E/A ratio) characteristics of fetuses with anemia, and to evaluate the performance of the inflow markers in predicting the affected fetuses.
METHODS: Fetuses at risk of hemoglobin (Hb) Bart's disease at 17-22 weeks were prospectively recruited to undergo echocardiography before diagnostic cordocentesis. Cardiac Doppler images were digitally stored for off-line blinded measurements of FTF and E/A ratio.
RESULTS: A total of 428 fetuses at risk of Hb Bart's disease were analyzed, including 88 affected fetuses (20.6%). The mean gestational age at the time of diagnosis was 19.43 ± 1.5 weeks. The FTFs in both sides were significantly lower in the affected fetuses, whereas the E/A ratios of both sides were significantly higher in the affected group. According to the receiver operating characteristic curves, the performance of the FTF of the right side in predicting affected fetuses was slightly better than that of the left side (area under curve: 0.707 versus 0.680, P < .001). Likewise, the performance of the E/A ratio of the tricuspid valve was slightly better than that of the mitral valve. Also, FTF was superior to E/A ratio in predicting the affected fetuses.
CONCLUSIONS: New insights leading to a better understanding of the fetal cardiac response to anemia are: 1) the FTFs in both sides were significantly decreased, suggesting some degree of diastolic ventricular dysfunction; 2) the E/A ratios of both sides were significantly increased, indicating volume load; and 3) The inflow parameters may be useful as a new predictor of fetal anemia, especially among pregnancies at risk.
引用
- Sirivat, Luewan, Srisupundit, et al. Fetal Cardiac Inflow Characteristics in Response to Fetal Anemia: Based on Fetal Hemoglobin Bart's Disease at Mid-Pregnancy. J Ultrasound Med. 2022. PMID: 36190159. doi:10.1002/jum.16109
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。