文献速递胸部技术与安全PETCT

基于18F-FDG PET/CT影像组学术前预测非小细胞肺癌纵隔淋巴结转移

Preoperative prediction of mediastinal lymph node metastasis in non-small cell lung cancer based on 18F-FDG PET/CT radiomics.
PubMed 文献 · Clin Radiol · 2022-10-01

本研究回顾性纳入155例NSCLC患者,从原发灶提取2704个影像组学特征并构建组学标签及列线图。组学标签在训练集和验证集预测纵隔淋巴结转移的AUC分别为0.851和0.826,列线图AUC分别为0.869和0.847,校准良好,决策曲线分析显示临床获益。

要点

  • 基于原发灶PET/CT影像组学特征可术前无创预测纵隔淋巴结转移。
  • 联合影像组学标签与年龄的列线图预测效能优于单一组学标签。
  • 列线图校准良好,决策曲线分析提示临床实用价值。

核心结论

  • 基于18F-FDG PET/CT的影像组学列线图整合组学标签与年龄,可用于NSCLC患者术前纵隔淋巴结转移的个体化预测。

研究设计与样本

  • 回顾性研究,纳入155例NSCLC患者,分为训练集93例和验证集62例。
  • 从原发肺癌区域提取2704个影像组学特征。
  • 采用Mann-Whitney U检验、Spearman相关分析、mRMR和LASSO二元logistic回归筛选特征并构建组学标签。
  • 基于组学标签与年龄建立列线图,评估区分度、校准度和临床实用性。

诊断标准与关键数值

  • 影像组学标签由8个筛选特征组成,训练集和验证集预测纵隔淋巴结转移的AUC分别为0.851和0.826。
  • 列线图在训练集和验证集预测纵隔淋巴结转移的AUC分别为0.869和0.847。

临床应用与阅片要点

  • 阅片时可关注原发灶PET/CT影像组学特征,结合年龄使用列线图辅助术前纵隔淋巴结转移风险评估。
  • 列线图预测效能良好且校准满意,决策曲线分析提示有临床实用价值,可辅助个体化治疗决策。

局限性

  • 回顾性研究设计。
  • 样本量有限,训练集93例、验证集62例。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To establish and verify a 2-[18F]-fluoro-2-deoxy-d-glucose (FDG) positron-emission tomography (PET)/computed tomography (CT)-based radiomics nomogram to predict mediastinal lymph node metastasis (LNM) in non-small cell lung cancer (NSCLC) patients preoperatively.

MATERIALS AND METHODS: This retrospective study enrolled 155 NSCLC patients (primary cohort, n=93; validation cohort, n=62). For each patient, 2,704 radiomic features were extracted from the primary lung cancer regions. Four procedures including the Mann-Whitney U-test, Spearman's correlation analysis, minimum redundancy-maximum relevance (mRMR), and least absolute shrinkage and selection operator (LASSO) binary logistic regression were utilised for determining essential features and establishing a radiomics signature. After that, a nomogram was established. The nomogram's potential was assessed based on its discrimination, calibration, and clinical usefulness. The radiomics signature and nomogram predictive performances were evaluated with respect to the area under the receiver operating characteristic curve (AUC), specificity, accuracy, and sensitivity.

RESULTS: The radiomics signature composed of eight selected features had good discriminatory performance of LNM versus non-LNM groups an AUC of 0.851 and 0.826 in primary and validation cohorts, respectively. The nomogram also indicated good discrimination with an AUC of 0.869 and 0.847 in the primary and validation cohorts, respectively. Furthermore, good calibration was demonstrated utilising the nomogram.

CONCLUSIONS: An 18F-FDG PET/CT-based radiomics nomogram that integrates the radiomics signature and age was promoted to predict mediastinal LNM within NSCLC patients, which could potentially facilitate individualised therapy for mediastinal LNM before treatment. The nomogram was beneficial in clinical practice, as illustrated by decision curve analysis.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Huang, Jiang, Xu, et al. Preoperative prediction of mediastinal lymph node metastasis in non-small cell lung cancer based on 18F-FDG PET/CT radiomics. Clin Radiol. 2022. PMID: 36192203. doi:10.1016/j.crad.2022.08.140

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。