文献速递心血管儿科影像US

自适应贝叶斯正则化心脏应变成像在小鼠缺血模型中对心脏重构的纵向监测:与组织学验证

In Vivo Longitudinal Monitoring of Cardiac Remodeling in Murine Ischemia Models With Adaptive Bayesian Regularized Cardiac Strain Imaging: Validation Against Histology.
PubMed 文献 · Ultrasound Med Biol · 2022-09-30

本研究旨在评估自适应贝叶斯正则化心脏应变成像(ABR-CSI)在小鼠缺血损伤模型(心肌梗死和缺血再灌注)中纵向监测心脏重构的可行性,并与组织学结果验证。30只BALB/CJ小鼠随机分为MI组(10只)、IR组(12只)和假手术组(8只),在术前及术后1、2、7、14天使用高频超声系统成像,通过ABR-CSI估算径向和纵向应变。结果显示ABR-CSI能无创地系列监测与MI和IR相关的不均匀心脏重构,径向应变在区分梗死区、边缘区和远程区方面优于纵向应变,且与组织学纤维化参数(PMF)有显著相关性。

要点

  • ABR-CSI可无创纵向监测小鼠心肌梗死和缺血再灌注后的心脏重构。
  • 径向收缩末期应变在区分梗死区、边缘区和远程区方面优于纵向应变。
  • 径向和纵向应变均与组织学纤维化参数PMF显著相关,径向应变相关性更高。

关键影像表现/征象

  • ABR-CSI通过术后应变估计的时间变化,能系列监测与小鼠MI和IR相关的不均匀心脏重构。
  • 径向收缩末期应变图像和节段应变曲线在区分梗死区、边缘区和远程区方面优于纵向应变结果。
  • MI组第14天前壁中部(梗死区)收缩末期径向应变值显著低于基线组(9.23 ± 7.39% vs 44.32 ± 5.49%,p=0.002)。
  • 前壁基底部(远程区)第14天平均收缩末期径向应变值与基线无显著差异(33.05 ± 6.99% vs 34.02 ± 6.75%,p=0.06)。

诊断标准与关键数值

  • 径向应变与PMF的Spearman相关系数εresρ = -0.67(n=172,p<0.001),纵向应变εlesρ = -0.60(n=172,p<0.001)。

临床应用与阅片要点

  • 在小动物缺血模型研究中,ABR-CSI可作为无创纵向监测心脏重构的工具。
  • 径向收缩末期应变图像和节段应变曲线有助于区分梗死区、边缘区和远程区。
  • 径向应变与组织学纤维化参数的相关性高于纵向应变,可能更适合评估纤维化。

局限性

  • 研究仅使用单一临床前高频超声系统,样本量较小(30只小鼠),结果推广需进一步验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Adaptive Bayesian regularized cardiac strain imaging (ABR-CSI) uses raw radiofrequency signals to estimate myocardial wall contractility as a surrogate measure of relative tissue elasticity incorporating regularization in the Bayesian sense. We determined the feasibility of using ABR-CSI -derived strain for in vivo longitudinal monitoring of cardiac remodeling in a murine ischemic injury model (myocardial infarction [MI] and ischemia-reperfusion [IR]) and validated the findings against ground truth histology. We randomly stratified 30 BALB/CJ mice (17 females, 13 males, median age = 10 wk) into three surgical groups (MI = 10, IR = 12, sham = 8) and imaged pre-surgery (baseline) and 1, 2, 7 and 14 d post-surgery using a pre-clinical high-frequency ultrasound system (VisualSonics Vevo 2100). We then used ABR-CSI to estimate end-systolic and peak radial (er) and longitudinal (el) strain estimates. ABR-CSI was found to have the ability to serially monitor non-uniform cardiac remodeling associated with murine MI and IR non-invasively through temporal variation of strain estimates post-surgery. Furthermore, radial end-systole (ES) strain images and segmental strain curves exhibited improved discrimination among infarct, border and remote regions around the myocardium compared with longitudinal strain results. For example, the MI group had significantly lower (Friedman's with Bonferroni-Dunn test, p = 0.002) ES er values in the anterior middle (infarcted) region at day 14 (n = 9, 9.23 ± 7.39%) compared with the BL group (n = 9, 44.32 ± 5.49). In contrast, anterior basal (remote region) mean ES er values did not differ significantly (non-significant Friedman's test, χ2 = 8.93, p = 0.06) at day 14 (n = 6, 33.05 ± 6.99%) compared with baseline (n = 6, 34.02 ± 6.75%). Histology slides stained with Masson's trichrome (MT) together with a machine learning model (random forest classifier) were used to derive the ground truth cardiac fibrosis parameter termed histology percentage of myocardial fibrosis (PMF). Both radial and longitudinal strain were found to have strong statistically significant correlations with the PMF parameter. However, radial strain had a higher Spearman's correlation value (εresρ = -0.67, n = 172, p < 0.001) compared with longitudinal strain (εlesρ = -0.60, n = 172, p < 0.001). Overall, the results of this study indicate that ABR-CSI can reliably perform non-invasive detection of infarcted and remote myocardium in small animal studies.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Mukaddim, Weichmann, Taylor, et al. In Vivo Longitudinal Monitoring of Cardiac Remodeling in Murine Ischemia Models With Adaptive Bayesian Regularized Cardiac Strain Imaging: Validation Against Histology. Ultrasound Med Biol. 2022. PMID: 36184393. doi:10.1016/j.ultrasmedbio.2022.07.012

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。