SWAVE 2.0 胎盘弹性与黏性成像:胎盘介导疾病检测的潜在生物标志物
本研究在46例离体胎盘(26例病变,20例正常)上评估改进的SWAVE 2.0系统,采用多频(80/100/120 Hz)和3-D局部频率估计测量弹性和黏性。IUGR和PE胎盘硬度显著高于正常胎盘,LDA分类器区分健康与病变胎盘的敏感度87%、特异度78%、AUC 0.90;黏性参数n在病变组显著升高。
要点
- SWAVE 2.0可无创定量胎盘弹性和黏性,病变胎盘(IUGR/PE)硬度显著高于正常。
- LDA分类器区分健康与病变胎盘的AUC为0.90,敏感度87%、特异度78%。
- 黏性参数n在IUGR和PE胎盘均显著高于正常胎盘。
关键影像表现/征象
- IUGR胎盘弹性值为15.30 ± 2.96 kPa,PE胎盘为12.33 ± 4.88 kPa,均显著高于正常胎盘8.32 ± 3.67 kPa(p=3.35e-5和p=0.017)。
- 黏性参数n在IUGR胎盘为2.3 ± 0.21,PE胎盘为2.11 ± 0.52,均显著高于正常胎盘1.45 ± 0.65。
- 体模实验显示3-D LFE较2-D方法降低弹性测量的偏差和方差。
诊断标准与关键数值
- LDA分类器区分健康与病变胎盘:敏感度87%、特异度78%、准确率83%、AUC 0.90(95%CI 0.8-0.99)。
- 预测新生儿ICU入住:敏感度70%、特异度71%、准确率71%、AUC 0.78(95%CI 0.62-0.93)。
临床应用与阅片要点
- 可尝试用SWAVE 2.0弹性值(IUGR约15 kPa、PE约12 kPa、正常约8 kPa)辅助识别胎盘异常。
- 黏性参数n升高(IUGR约2.3、PE约2.1、正常约1.45)可作为附加指标。
- 注意本研究为离体胎盘测量,活体应用需考虑深度、安全性和运动伪影。
局限性
- 研究在离体胎盘上进行,未在活体妊娠中验证。
- 样本量有限(46例),病变组中IUGR和PE例数较少。
- 未报告多中心验证或操作者重复性数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Pregnancy complications such as pre-eclampsia (PE) and intrauterine growth restriction (IUGR) are associated with structural and functional changes in the placenta. Different elastography techniques with an ability to assess the mechanical properties of tissue can identify and monitor the pathological state of the placenta. Currently available elastography techniques have been used with promising results to detect placenta abnormalities; however, limitations include inadequate measurement depth and safety concerns from high negative pressure pulses. Previously, we described a shear wave absolute vibro-elastography (SWAVE) method by applying external low-frequency mechanical vibrations to generate shear waves and studied 61 post-delivery clinically normal placentas to explore the feasibility of SWAVE for placental assessment and establish a measurement baseline. This next phase of the study, namely, SWAVE 2.0, improves the previous system and elasticity reconstruction by incorporating a multi-frequency acquisition system and using a 3-D local frequency estimation (LFE) method. Compared with its 2-D counterpart, the proposed system using 3-D LFE was found to reduce the bias and variance in elasticity measurements in tissue-mimicking phantoms. In the aim of investigating the potential of improved SWAVE 2.0 measurements to identify placental abnormalities, we studied 46 post-delivery placentas, including 26 diseased (16 IUGR and 10 PE) and 20 normal control placentas. By use of a 3.33-MHz motorized curved-array transducer, multi-frequency (80,100 and 120 Hz) elasticity measures were obtained with 3-D LFE, and both IUGR (15.30 ± 2.96 kPa, p = 3.35e-5) and PE (12.33 ± 4.88 kPa, p = 0.017) placentas were found to be significantly stiffer compared with the control placentas (8.32 ± 3.67 kPa). A linear discriminant analysis (LDA) classifier was able to classify between healthy and diseased placentas with a sensitivity, specificity and accuracy of 87%, 78% and 83% and an area under the receiver operating curve of 0.90 (95% confidence interval: 0.8-0.99). Further, the pregnancy outcome in terms of neonatal intensive care unit admission was predicted with a sensitivity, specificity and accuracy of 70%, 71%, 71%, respectively, and area under the receiver operating curve of 0.78 (confidence interval: 0.62-0.93). A viscoelastic characterization of placentas using a fractional rheological model revealed that the viscosity measures in terms of viscosity parameter n were significantly higher in IUGR (2.3 ± 0.21) and PE (2.11 ± 0.52) placentas than in normal placentas (1.45 ± 0.65). This work illustrates the potential relevance of elasticity and viscosity imaging using SWAVE 2.0 as a non-invasive technology for detection of placental abnormalities and the prediction of pregnancy outcomes.
引用
- Deeba, Hu, Lessoway, et al. SWAVE 2.0 Imaging of Placental Elasticity and Viscosity: Potential Biomarkers for Placenta-Mediated Disease Detection. Ultrasound Med Biol. 2022. PMID: 36180312. doi:10.1016/j.ultrasmedbio.2022.08.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。