基于深度学习重建的超快速颈椎MRI协议:与常规协议的诊断等效性
三位神经放射学家对退行性改变分级,除终板退变外,所有变量的个体等效指数95%CI均未超过5%,提示两种协议可互换,kappa值0.600-0.977显示高度到几乎完美的一致性。
要点
- 超快速颈椎MRI协议(2分57秒)除终板退变外,与常规协议诊断结果可互换。
- 深度学习重建可补偿加速导致的信噪比下降,保证图像判读一致性。
- 阅片者间一致性kappa值0.600-0.977,范围从高度到几乎完美。
关键影像表现/征象
- 超快速协议通过降低相位矩阵、过采样率和激励次数并应用压缩感知,将采集时间缩短至常规协议约四分之一。
- 采用深度学习重建进行降噪,以补偿加速导致的信噪比下降。
- 判读内容包括中央椎管狭窄、椎间孔狭窄、终板退变、椎间盘退变和椎间盘突出,并记录其他病变存在。
诊断标准与关键数值
- 除终板退变外,所有变量的个体等效指数95%CI均未超过5%,表明两种协议可互换。
- 协议间阅片者内一致性kappa值为0.600-0.977,提示高度到几乎完美一致。
临床应用与阅片要点
- 超快速颈椎MRI协议可用于临床,显著缩短检查时间而不影响大多数退行性改变的判读。
- 终板退变的评估在超快速协议与常规协议间可能不完全等效,报告时需注意。
局限性
- 研究缺乏参考标准,采用等效性检验而非与金标准比较。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: A major drawback of magnetic resonance imaging (MRI) is its limited imaging speed. This study proposed an ultrafast cervical spine MRI protocol (2 min 57 s) using deep learning-based reconstruction (DLR) and compared the diagnostic results to those of conventional MRI protocols (12 min 54 s).
METHODS: Fifty patients who underwent cervical spine MRI using both conventional and ultrafast protocols, including sagittal T1-weighted, T2-weighted, short-TI inversion recovery, and axial T2*-weighted imaging were included in this study. The ultrafast protocol shortened the acquisition time to approximately-one-fourth of that of the conventional protocol by reducing the phase matrix, oversampling rate, and number of excitations, and by applying compressed sensing. To compensate for the decreased signal-to-noise ratio caused by acceleration, noise reduction using DLR was performed. For image interpretation, three neuroradiologists graded or classified degenerative changes, including central canal stenosis, foraminal stenosis, endplate degeneration, disc degeneration, and disc hernia. The presence of other pathologies was also recorded. Given the absence of a reference standard, we tested the interchangeability of the two protocols by calculating the 95% confidence interval (CI) of the individual equivalence index. We also assessed the inter-protocol intra-reader agreement using kappa statistics.
RESULTS: Except for endplate degeneration, the 95 % CI of the individual equivalence index for all variables did not exceed 5 %, indicating interchangeability between the two protocols. The kappa values ranged from 0.600 to 0.977, indicating substantial to almost perfect agreement.
CONCLUSIONS: The proposed ultrafast MRI protocol yielded almost equivalent diagnostic results compared as the conventional protocol.
引用
- Kashiwagi, Sakai, Tsukabe, et al. Ultrafast cervcial spine MRI protocol using deep learning-based reconstruction: Diagnostic equivalence to a conventional protocol. Eur J Radiol. 2022. PMID: 36179465. doi:10.1016/j.ejrad.2022.110531
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。