MRI测量纵隔移位角用于先天性膈疝胎儿产前风险分层
本研究回顾性分析87例产前诊断左侧先天性膈疝胎儿和88例对照,在MRI上测量纵隔移位角(MSA),并与肺面积/头围比(LHR)、观察/预期LHR(O/E LHR)、总胎儿肺体积(TFLV)及观察/预期TFLV(O/E TFLV)比较。结果显示MSA在CDH组与对照组间及不同生存结局的CDH患者间均有显著差异,MSA与O/E LHR、O/E TFLV、TFLV呈负相关,可预测生存,其预测性能与TFLV、O/E TFLV、O/E LHR相似但优于LHR,且与肺动脉高压、ECMO使用及住院时间相关。
要点
- MSA可在MRI上快速、可重复测量,用于产前左侧CDH风险分层。
- MSA预测生存的性能与TFLV、O/E TFLV、O/E LHR相似,优于LHR。
- MSA还与肺动脉高压、ECMO需求及住院时间相关,提供生存外预后信息。
核心结论
- MRI测量MSA可为产前诊断的左侧CDH提供多种预后信息,包括生存、肺动脉高压、ECMO使用和住院时间。
- MSA的预测性能与TFLV、O/E TFLV和O/E LHR相似,但优于LHR。
研究设计与样本
- 回顾性分析87例产前诊断左侧CDH胎儿和88例对照,在MRI上测量MSA、LHR、O/E LHR、TFLV和O/E TFLV。
- 分析MSA与新生儿肺动脉高压、ECMO使用、住院时间和生存的相关性,并比较MSA与LHR、O/E LHR、TFLV、O/E TFLV预测出生后结局的性能。
诊断标准与关键数值
- MSA在CDH组与对照组间以及不同生存结局的CDH患者间均有显著差异。
- MSA与O/E LHR、O/E TFLV和TFLV呈负相关。
- ROC曲线显示MSA预测生存的性能与TFLV、O/E TFLV和O/E LHR相似,但优于LHR。
临床应用与阅片要点
- 可将MSA纳入左侧CDH胎儿的产前风险分层,以改善出生后管理计划。
- MSA测量快速且可重复,适合在日常胎儿MRI阅片中应用。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the predictive value of mediastinal shift angle (MSA) in congenital diaphragmatic hernia (CDH).
METHODS: A retrospective analysis was performed on 87 fetuses with prenatally diagnosed left-sided CDH (LCDH) and 88 controls. MSA was measured on magnetic resonance imaging (MRI). Lung area to head circumference ratio (LHR), ratio of the observed/expected LHR (O/E LHR), total fetal lung volume (TFLV), and observed/expected total fetal lung volume (O/E TFLV) were also measured. Correlation of MSA with pulmonary hypertension (PH), extracorporeal membrane oxygenation (ECMO) use, duration of hospitalization and survival in neonates with CDH was analyzed. Performance of MSA in prediction of postnatal outcomes was compared with LHR, O/E LHR, TFLV, and O/E TFLV.
RESULTS: There were significant differences in MSA values not only between the CDH group and the control group but also in CDH patients with different survival outcomes. MSA was inversely correlated with O/E LHR, O/E TFLV, and TFLV. MSA, LHR, O/E LHR, TFLV, and O/E TFLV could all be used to predict survival of CDH patients. In addition, the receiver operating characteristic (ROC) curve showed that the test performance of MSA was similar to that of TFLV, O/E TFLV, and O/E LHR, but superior to that of LHR. MSA was also correlated with PH, need for ECMO support, and duration of hospitalization.
CONCLUSION: MRI measurement of MSA can provide various prognostic information for prenatally diagnosed LCDH, in addition to postnatal survival. The test performance of MSA is similar to TFLV, O/E TFLV, and O/E LHR.
KEY POINTS: • Mediastinal shift angle (MSA) can be measured quickly and reproducibly on MRI images. • MSA could provide more prognostic information other than postnatal survival for LCDH with good test performance. • MSA should be incorporated into prenatal risk stratification for LCDH to improve planning of postnatal management.
引用
- Ding, Gu, Wu, et al. Mediastinal shift angle (MSA) measurement with MRI: a simple and effective tool for prenatal risk stratification in fetuses with congenital diaphragmatic hernia. Eur Radiol. 2022. PMID: 36180644. doi:10.1007/s00330-022-09142-2
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。