文献速递神经头颈儿科影像CTMR

耳蜗偏移的客观评估:耳蜗转角对齐率在腮耳肾综合征诊断中的应用

The Cochlea in Branchio-Oto-Renal Syndrome: An Objective Method for the Diagnosis of Offset Cochlear Turns.
PubMed 文献 · AJNR Am J Neuroradiol · 2022-09-29

本研究回顾性分析40例腮耳肾综合征患者及40例对照的颞骨CT或MR,提出耳蜗转角对齐率(turn alignment ratio)作为客观评估耳蜗偏移的指标,并确定最佳截断值为0.476(敏感度1,特异度0.986),能准确区分EYA1型腮耳肾综合征与SIX1型及健康对照。

要点

  • 耳蜗转角对齐率<0.476提示耳蜗偏移,与EYA1型腮耳肾综合征高度相关。
  • 该指标可客观区分EYA1型与SIX1型腮耳肾综合征及健康对照。
  • 传统主观视觉评估耳蜗偏移可借助此定量方法提高一致性。

关键影像表现/征象

  • 耳蜗偏移表现为耳蜗转角排列不齐,可通过转角对齐率定量评估。
  • EYA1型腮耳肾综合征除1个耳蜗外均存在耳蜗偏移且转角对齐率<0.476。
  • SIX1型腮耳肾综合征除1个耳蜗外及所有对照均无偏移且转角对齐率>0.476。

诊断标准与关键数值

  • 耳蜗转角对齐率最佳截断值0.476,区分偏移与非偏移耳蜗的敏感度=1,特异度=0.986,J=0.986,P<.001。
  • 耳蜗偏移主观评估由2名独立盲法读者完成,定量通过标准化技术计算转角对齐率。
  • 腮耳肾综合征基因亚型包括EYA1、SIX1及未知基因型。

临床应用与阅片要点

  • 在颞骨影像报告中可定量测量耳蜗转角对齐率,以0.476为阈值辅助识别耳蜗偏移。
  • 对于疑似腮耳肾综合征患者,发现耳蜗偏移提示可能为EYA1基因突变相关。
  • 注意SIX1型腮耳肾综合征及健康对照通常无耳蜗偏移,转角对齐率>0.476。

局限性

  • 仅纳入40例腮耳肾综合征患者,基因亚型分布未详细说明。
  • 未报告设备参数、序列细节及读者间一致性数据。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND AND PURPOSE: An "unwound" or "offset" cochlea has been described as a characteristic imaging feature in patients with branchio-oto-renal syndrome, and recently recognized to be associated in particular to those with EYA1 gene mutations. Determination of this feature has traditionally relied on subjective visual assessment. Our aim was to establish an objective assessment method for cochlear offset (the cochlear turn alignment ratio) and determine an optimal cutoff turn alignment ratio value that separates individuals with EYA1-branchio-oto-renal syndrome from those with SIX1-branchio-oto-renal syndrome and healthy controls.

MATERIALS AND METHODS: Temporal bone CT or MR imaging from 40 individuals with branchio-oto-renal syndrome and 40 controls was retrospectively reviewed. Cochlear offset was determined visually by 2 independent blinded readers and then quantitatively via a standardized technique yielding the cochlear turn alignment ratio. The turn alignment ratio values were compared between cochleae qualitatively assessed as "not offset" and "offset." Receiver operating characteristic analysis was used to determine the ability of the turn alignment ratio to differentiate between these populations and an optimal cutoff turn alignment ratio value. Cochlear offset and turn alignment ratio values were analyzed for each branchio-oto-renal syndrome genotype subpopulation and for controls.

RESULTS: The turn alignment ratio can accurately differentiate between cochleae with and without an offset (P < .001). The optimal cutoff value separating these populations was 0.476 (sensitivity = 1, specificity = 0.986, J = 0.986). All except 1 cochlea among the EYA1-branchio-oto-renal syndrome subset and all with unknown genotype branchio-oto-renal syndrome had a cochlear offset and a turn alignment ratio of <0.476. All except 1 cochlea among the SIX1-branchio-oto-renal syndrome subset and all controls had no offset and a turn alignment ratio of >0.476.

CONCLUSIONS: There is a statistically significant difference in turn alignment ratios between offset and nonoffset cochleae, with an optimal cutoff of 0.476. This cutoff value allows excellent separation of EYA1-branchio-oto-renal syndrome from SIX1-branchio-oto-renal syndrome and from individuals without branchio-oto-renal syndrome or sensorineural hearing loss. The turn alignment ratio is a reliable and objective metric that can aid in the imaging evaluation of branchio-oto-renal syndrome.

来源:AJNR Am J Neuroradiol,查看原文。版权归原作者所有。

引用

  1. Juliano, D'Arco, Pao, et al. The Cochlea in Branchio-Oto-Renal Syndrome: An Objective Method for the Diagnosis of Offset Cochlear Turns. AJNR Am J Neuroradiol. 2022. PMID: 36175083. doi:10.3174/ajnr.A7653

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。