人工智能辅助儿童及青年附肢骨骼骨折检测:资深与初级放射科医师评估
本研究回顾性纳入300例2-21岁患者附肢骨折X线片,由3名资深儿科放射科医师和5名住院医师分别在不使用AI和立即使用AI辅助下阅片。AI辅助使平均敏感度从73.3%显著提高至82.8%(P<0.001),特异度无显著变化(89.6%至90.3%,P=0.28)。AI独立敏感度和特异度分别为91%和90%。
要点
- AI辅助可显著提高骨折检出敏感度约10%,尤其对初级医师提升更明显(+10.3%)。
- AI辅助不显著降低特异度,资深医师特异度基本不变(95.1%至94.9%)。
- AI独立诊断敏感度91%、特异度90%,可作为辅助工具但需医师复核。
诊断标准与关键数值
- AI辅助前平均敏感度73.3%(110/150),辅助后82.8%(125/150),提高约10%(P<0.001)。
- 初级放射科医师敏感度提高10.3%(P<0.001),资深放射科医师提高8.2%(P=0.08)。
- 平均特异度从89.6%变为90.3%(+0.7%,P=0.28);初级医师从86.2%升至87.6%(+1.4%,P=0.42),资深医师从95.1%降至94.9%(-0.2%,P=0.23)。
- AI独立敏感度和特异度分别为91%和90%。
临床应用与阅片要点
- 在儿科急诊X线阅片中,AI辅助可提高骨折检出率,尤其适合初级医师使用。
- AI辅助不降低特异度,但资深医师特异度略有下降,需注意假阳性风险。
- AI独立性能较高,但仍需医师结合临床和影像综合判断。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: As the number of conventional radiographic examinations in pediatric emergency departments increases, so, too, does the number of reading errors by radiologists.
OBJECTIVE: The aim of this study is to investigate the ability of artificial intelligence (AI) to improve the detection of fractures by radiologists in children and young adults.
MATERIALS AND METHODS: A cohort of 300 anonymized radiographs performed for the detection of appendicular fractures in patients ages 2 to 21 years was collected retrospectively. The ground truth for each examination was established after an independent review by two radiologists with expertise in musculoskeletal imaging. Discrepancies were resolved by consensus with a third radiologist. Half of the 300 examinations showed at least 1 fracture. Radiographs were read by three senior pediatric radiologists and five radiology residents in the usual manner and then read again immediately after with the help of AI.
RESULTS: The mean sensitivity for all groups was 73.3% (110/150) without AI; it increased significantly by almost 10% (P<0.001) to 82.8% (125/150) with AI. For junior radiologists, it increased by 10.3% (P<0.001) and for senior radiologists by 8.2% (P=0.08). On average, there was no significant change in specificity (from 89.6% to 90.3% [+0.7%, P=0.28]); for junior radiologists, specificity increased from 86.2% to 87.6% (+1.4%, P=0.42) and for senior radiologists, it decreased from 95.1% to 94.9% (-0.2%, P=0.23). The stand-alone sensitivity and specificity of the AI were, respectively, 91% and 90%.
CONCLUSION: With the help of AI, sensitivity increased by an average of 10% without significantly decreasing specificity in fracture detection in a predominantly pediatric population.
引用
- Nguyen, Maarek, Hermann, et al. Assessment of an artificial intelligence aid for the detection of appendicular skeletal fractures in children and young adults by senior and junior radiologists. Pediatr Radiol. 2022. PMID: 36169667. doi:10.1007/s00247-022-05496-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。