基于2017分类的肝细胞腺瘤亚型:钆塞酸二钠增强MRI特征探索性研究及诊断算法提议

Hepatocellular Adenoma Subtypes Based on 2017 Classification System: Exploratory Study of Gadoxetate Disodium-Enhanced MRI Features With Proposal of a Diagnostic Algorithm.
PubMed 文献 · AJR Am J Roentgenol · 2022-09-28

该回顾性研究纳入56例病理确诊肝细胞腺瘤患者共65个病灶,按2017分类重新分型并评估钆塞酸二钠增强MRI特征。结果显示肝胆期等/高信号在β-HCA/β-IHCA中占80%、其他亚型仅5%,据此提出的诊断算法对HHCA、IHCA、β-HCA/β-IHCA准确率分别为98%、83%、95%。

要点

  • 肝胆期等或高信号强烈提示β-catenin外显子3激活型或混合炎症型腺瘤。
  • 病灶内弥漫均匀脂肪变几乎仅见于HNF1α突变型腺瘤(94%)。
  • 「环礁征」和中度T2高信号更多见于炎症型腺瘤,可辅助分型。

关键影像表现/征象

  • HNF1α突变型腺瘤94%表现为病灶内弥漫均匀脂肪变,其他亚型均为0%。
  • 炎症型腺瘤58%见「环礁征」、52%呈中度T2高信号,其他亚型分别为12%和12%。
  • β-catenin激活型及混合炎症β型60%见液性成分、80%肝胆期呈等或高信号,其他亚型分别为5%和5%。
  • β-catenin激活型及混合炎症β型更多见于男性(63% vs 4%),平均更大(10.1±6.8 cm vs 5.1±2.9 cm)。
  • shHCA与未分类腺瘤未见可鉴别的影像特征。

诊断标准与关键数值

  • 所提诊断算法对HHCA准确率98%、对IHCA准确率83%、对β-HCA或β-IHCA准确率95%。
  • 肝胆期肝-病灶对比增强比(LLCER)阳性见于9个腺瘤(8个为β-HCA/β-IHCA,1个为IHCA)。

临床应用与阅片要点

  • 阅片时应重点观察肝胆期信号:等或高信号需警惕β-catenin外显子3激活型,提示恶性潜能需进一步处理。
  • 发现病灶内弥漫均匀脂肪变时优先考虑HNF1α突变型,可减少不必要的活检。
  • 男性、大病灶(平均约10 cm)、含液性成分及肝胆期等/高信号组合时,应报告β-catenin激活型可能。
  • 「环礁征」和中度T2高信号支持炎症型腺瘤诊断。

局限性

  • 单中心回顾性设计,样本量较小且部分亚型(如β-HCA、β-IHCA、shHCA、UHCA)病灶数很少。
  • shHCA与未分类腺瘤未显示可鉴别特征,算法对这些亚型价值有限。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND. The classification of hepatocellular adenomas (HCAs) was updated in 2017 on the basis of genetic and molecular analysis. OBJECTIVE. The purpose of this article was to evaluate features on gadoxetate disodium-enhanced MRI of HCA subtypes on the basis of the 2017 classification and to propose a diagnostic algorithm for determining subtype using these features. METHODS. This retrospective study included 56 patients (49 women, seven men; mean age, 37 ± 13 [SD] years) with histologically confirmed HCA evaluated by gadoxetate disodium-enhanced MRI from January 2010 to January 2021. Subtypes were reclassified using 2017 criteria: hepatocyte nuclear factor-1α mutated HCA (HHCA), inflammatory HCA (IHCA), β-catenin exon 3 activated HCA (β-HCA), mixed inflammatory and β-HCA (β-IHCA), sonic hedgehog HCA (shHCA), and unclassified HCA (UHCA). Qualitative MRI features were assessed. Liver-to-lesion contrast enhancement ratios (LLCERs) were measured. Subtypes were compared, and a diagnostic algorithm was proposed. RESULTS. The analysis included 65 HCAs: 16 HHCAs, 31 IHCAs, six β-HCA, four β-IHCA, five shHCA, and three UHCAs. HHCAs showed homogeneous diffuse intralesional steatosis in 94%, whereas all other HCAs showed this finding in 0% (p < .001). IHCAs showed the "atoll" sign in 58%, whereas all other HCAs showed this finding in 12% (p < .001). IHCAs showed moderate T2 hyperintensity in 52%, whereas all other HCAs showed this finding in 12% (p < .001). The β-HCAs and β-IHCAs occurred in men in 63%, whereas all other HCAs occurred in men in 4% (p < .001). The β-HCAs and β-IHCAs had a mean size of 10.1 ± 6.8 cm, whereas all other HCAs had a mean size of 5.1 ± 2.9 cm (p = .03). The β-HCAs and β-IHCAs showed fluid components in 60%, whereas all other HCAs showed this finding in 5% (p < .001). Hepatobiliary phase iso- or hyperintensity was observed in 80% of β-HCAs and β-IHCAs versus 5% of all other HCAs (p < .001). Hepatobiliary phase LLCER was positive in nine HCAs (eight β-HCAs and β-IHCAs; one IHCA). The shHCA and UHCA did not show distinguishing features. The proposed diagnostic algorithm had accuracy of 98% for HHCAs, 83% for IHCAs, and 95% for β-HCAs or β-IHCAs. CONCLUSION. Findings on gadoxetate disodium-enhanced MRI, including hepatobiliary phase characteristics, were associated with HCA subtypes using the 2017 classification. CLINICAL IMPACT. The algorithm identified common HCA subtypes with high accuracy, including those with β-catenin exon 3 mutations.

来源:AJR Am J Roentgenol,查看原文。版权归原作者所有。

引用

  1. Tse, Felker, Cao, et al. Hepatocellular Adenoma Subtypes Based on 2017 Classification System: Exploratory Study of Gadoxetate Disodium-Enhanced MRI Features With Proposal of a Diagnostic Algorithm. AJR Am J Roentgenol. 2022. PMID: 36169546. doi:10.2214/AJR.22.28233

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。