三维多段线辅助锥形束CT引导经皮肺穿刺活检
回顾性分析122例患者(男81例,女41例,年龄65±12岁)采用锥形束CT虚拟导航联合三维多段线(3DP)引导经皮肺穿刺活检。病灶平均大小23±13 mm,总体诊断准确率94.3%,可见与不可见病灶准确率无差异(94.0% vs 94.9%,p=0.843),小肺结节(≤1 cm)准确率100%。主要并发症发生率8.2%。
要点
- 3DP引导可实时勾勒病灶轮廓,提高穿刺准确性。
- 小肺结节(≤1 cm)诊断准确率达100%,尤其适用于此类病灶。
- 主要并发症发生率8.2%,包括气胸需置管、咯血需输血和空气栓塞。
核心结论
- CBCT虚拟导航联合3DP引导可提供病灶实时轮廓,实现可靠且准确的经皮肺穿刺活检。
关键影像表现/征象
- 病灶平均大小23±13 mm(范围6-75 mm),13.9%(17/122)为小肺结节(直径≤1 cm),68.0%(83/122)病灶在透视下可见。
诊断标准与关键数值
- 总体诊断准确率94.3%;透视可见病灶准确率94.0%,不可见病灶94.9%(p=0.843);小肺结节(≤1 cm)准确率100%。
临床应用与阅片要点
- 3DP引导尤其适用于小肺结节(≤1 cm)的穿刺活检,透视不可见病灶仍可获得与可见病灶相当的诊断准确率。
局限性
- 回顾性研究,样本量有限(122例),单中心,随访时间短。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To investigate the diagnostic accuracy of using 3D polylines (3DPs) to improve cone-beam CT (CBCT) virtual navigation (VN)-guided percutaneous transthoracic needle biopsies (PTNB) of pulmonary lesions.
METHODS: From May 2021 to November 2021, patients (81 males and 41 females; age, 65 ± 12 years) who underwent CBCT VN with 3DPs for PTNB of pulmonary lesions were retrospectively reviewed. Fluoroscopic visibility of target lesions was evaluated using captured images from a Bull's eye view. Diagnostic accuracy was calculated, and complications were assessed.
RESULTS: The mean size of biopsied lesions was 23 ± 13 mm (range: 6-75 mm). Overall, 13.9% (17/122) were small pulmonary nodules (diameter ≤1 cm), and 68.0% (83/122) of biopsied lesions were fluoroscopic visible. The overall diagnostic accuracy was 94.3%. The diagnostic accuracy for visible and invisible lesions was 94.0 and 94.9%, respectively (p = 0.843), and 100% for small pulmonary nodules. Major complications occurred in 8.2% (10/122; eight pneumothorax with chest tube insertion, one hemoptysis with transfusion, and one air embolism) of patients.
CONCLUSION: CBCT VN with 3DP guidance provide a real-time outline of pulmonary lesions, thus enabling a reliable and accurate PTNB.
ADVANCES IN KNOWLEDGE: 3DP guidance could be useful technique for CBCT-guided PTNB, especially in small pulmonary nodules.
引用
- Han, Kim. Using 3D polylines to improve cone-beam CT-guided percutaneous transthoracic needle biopsy. Br J Radiol. 2022. PMID: 36169413. doi:10.1259/bjr.20220406
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。