基于放射组学特征的机器学习模型在平扫CT上检测早期脑干梗死
本研究基于多中心355例平扫CT数据,提取1781个放射组学特征并构建7种机器学习模型检测早期脑干梗死,多层感知器模型内部验证AUC为0.99(95%CI 0.96-1.00),外部验证AUC为0.91(95%CI 0.82-0.98),提示该模型有望辅助平扫CT早期诊断。
要点
- 多层感知器放射组学模型在平扫CT上检测早期脑干梗死性能最佳,外部验证AUC达0.91。
- 模型适用于多种多探测器CT扫描仪,有望缩短治疗决策时间。
- 平扫CT对早期脑干梗死检出率目前很低,该模型可作为计算机辅助诊断工具。
核心结论
- 基于放射组学特征的机器学习模型在平扫CT上检测早期脑干梗死具有较高准确性,多层感知器模型内部验证AUC为0.99(95%CI 0.96-1.00),外部验证AUC为0.91(95%CI 0.82-0.98)。
研究设计与样本
- 由放射科医师委员会在平扫CT上分割脑干,自动计算1781个放射组学特征,筛选后评估7种机器学习模型。
诊断标准与关键数值
- 多层感知器模型在内部验证队列AUC为0.99(95%CI 0.96-1.00),外部验证队列AUC为0.91(95%CI 0.82-0.98)。
- 模型性能评估指标包括准确率、敏感度、特异度、阳性预测值、阴性预测值、F1分数和AUC。
临床应用与阅片要点
- 该模型可作为平扫CT上早期脑干梗死的计算机辅助诊断工具,帮助缩短治疗决策时间。
- 模型适用于多种多探测器CT扫描仪,但需注意其基于放射组学特征,实际阅片时应结合临床和影像征象综合判断。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: Magnetic resonance imaging has high sensitivity in detecting early brainstem infarction (EBI). However, MRI is not practical for all patients who present with possible stroke and would lead to delayed treatment. The detection rate of EBI on non-contrast computed tomography (NCCT) is currently very low. Thus, we aimed to develop and validate the radiomics feature-based machine learning models to detect EBI (RMEBIs) on NCCT.
METHODS: In this retrospective observational study, 355 participants from a multicentre multimodal database established by Huashan Hospital were randomly divided into two data sets: a training cohort (70%) and an internal validation cohort (30%). Fifty-seven participants from the Second Affiliated Hospital of Xuzhou Medical University were included as the external validation cohort. Brainstems were segmented by a radiologist committee on NCCT and 1781 radiomics features were automatically computed. After selecting the relevant features, 7 machine learning models were assessed in the training cohort to predict early brainstem infarction. Accuracy, sensitivity, specificity, positive predictive value, negative predictive value, F1-score, and the area under the receiver operating characteristic curve (AUC) were used to evaluate the performance of the prediction models.
RESULTS: The multilayer perceptron (MLP) RMEBI showed the best performance (AUC: 0.99 [95% CI: 0.96-1.00]) in the internal validation cohort. The AUC value in external validation cohort was 0.91 (95% CI: 0.82-0.98).
CONCLUSIONS: RMEBIs have the potential in routine clinical practice to enable accurate computer-assisted diagnoses of early brainstem infarction in patients with NCCT, which may have important clinical value in reducing therapeutic decision-making time.
KEY POINTS: • RMEBIs have the potential to enable accurate diagnoses of early brainstem infarction in patients with NCCT. • RMEBIs are suitable for various multidetector CT scanners. • The patient treatment decision-making time is shortened.
引用
- Zhang, Chen, Zhang, et al. A radiomics feature-based machine learning models to detect brainstem infarction (RMEBI) may enable early diagnosis in non-contrast enhanced CT. Eur Radiol. 2022. PMID: 36169689. doi:10.1007/s00330-022-09130-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。