光子计数探测器CT冠状动脉CTA对比剂减量:动态体模研究

Reduced Iodinated Contrast Media Administration in Coronary CT Angiography on a Clinical Photon-Counting Detector CT System: A Phantom Study Using a Dynamic Circulation Model.
PubMed 文献 · Invest Radiol · 2022-09-13

本研究利用动态循环体模评估第一代双源光子计数探测器CT在冠状动脉CT血管成像中减少碘对比剂用量的可行性。结果显示,在40 keV虚拟单能图像重建下,对比剂浓度可降低50%仍可获得诊断性衰减和客观图像质量,但20%浓度衰减不足。结论需临床研究验证。

要点

  • 40 keV虚拟单能重建下对比剂浓度可减半仍满足诊断。
  • 标准临床方案所有重建冠状动脉衰减均>398 HU。
  • 20%对比剂浓度所有重建均衰减不足。

关键影像表现/征象

  • 标准临床对比剂方案(100%浓度)所有重建冠状动脉衰减均>398 HU。
  • 50%浓度降低在40-55 keV虚拟单能图像上冠状动脉衰减>366 HU。
  • 40%和30%浓度分别在40-45 keV和40 keV虚拟单能图像上达到满意衰减。
  • 20%浓度所有重建均衰减不足。
  • 所有注射方案中40 keV虚拟单能重建的CNR最高,50%浓度降低时CNR足够。

诊断标准与关键数值

  • 以衰减350 HU和参考方案70 keV的CNR作为诊断充分性标准。
  • 标准方案(100%浓度)所有重建冠状动脉衰减>398 HU。
  • 50%浓度降低在40-55 keV衰减>366 HU。
  • 40%浓度在40-45 keV、30%浓度在40 keV达到满意衰减。
  • 20%浓度所有重建衰减不足。

临床应用与阅片要点

  • 在光子计数探测器CT冠状动脉CTA中,可考虑使用40 keV虚拟单能图像重建以降低对比剂浓度。
  • 对比剂浓度降低50%时仍可满足诊断,但需注意20%浓度衰减不足。
  • 需在临床研究中验证体模结果。

局限性

  • 体模研究,结果需临床研究验证。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: The aim of this study was to evaluate strategies to reduce contrast media volumes for coronary computed tomography (CT) angiography on a clinical first-generation dual-source photon-counting detector (PCD)-CT system using a dynamic circulation phantom.

MATERIALS AND METHODS: Coronary CT angiograph is an established method for the assessment of coronary artery disease that relies on the administration of iodinated contrast media. Reduction of contrast media volumes while maintaining diagnostic image quality is desirable. In this study, a dynamic phantom containing a 3-dimensional-printed model of the thoracic aorta and coronary arteries was evaluated using a clinical contrast injection protocol with stepwise reduced contrast agent concentrations (100%, 75%, 50%, 40%, 30%, and 20% contrast media content of the same 50 mL bolus, resulting in iodine delivery rates of 1.5, 1.1, 0.7, 0.6, 0.4 and 0.3 gl/s) on a first-generation, dual-source PCD-CT. Polychromatic images (T3D) and virtual monoenergetic images were reconstructed in the range of 40 to 70 keV in 5-keV steps. Attenuation and noise were measured in the coronary arteries and background material and the contrast-to-noise ratio (CNR) were calculated. Attenuation of 350 HU and a CNR of the reference protocol at 70 keV were regarded as sufficient for simulation of diagnostic purposes. Vessel sharpness and noise power spectra were analyzed for the aforementioned reconstructions.

RESULTS: The standard clinical contrast protocol (bolus with 100% contrast) yielded diagnostic coronary artery attenuation for all tested reconstructions (>398 HU). A 50% reduction in contrast media concentration demonstrated sufficient attenuation of the coronary arteries at 40 to 55 keV (>366 HU). Virtual monoenergetic image reconstructions of 40 to 45 and 40 keV allowed satisfactory attenuation of the coronary arteries for contrast concentrations of 40% and 30% of the original protocol. A reduction of contrast agent concentration to 20% of the initial concentration provided insufficient attenuation in the target vessels for all reconstructions. The highest CNR was found for virtual monoenergetic reconstructions at 40 keV for all contrast media injection protocols, yielding a sufficient CNR at a 50% reduction of contrast agent concentration.

CONCLUSIONS: Using virtual monoenergetic image reconstructions at 40 keV on a dual-source PCD-CT system, contrast media concentration could be reduced by 50% to obtain diagnostic attenuation and objective image quality for coronary CT angiography in a dynamic vessel phantom. These initial feasibility study results have to be validated in clinical studies.

来源:Invest Radiol,查看原文。版权归原作者所有。

引用

  1. Emrich, O'Doherty, Schoepf, et al. Reduced Iodinated Contrast Media Administration in Coronary CT Angiography on a Clinical Photon-Counting Detector CT System: A Phantom Study Using a Dynamic Circulation Model. Invest Radiol. 2022. PMID: 36165932. doi:10.1097/RLI.0000000000000911

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。