文献速递胸部技术与安全US

床旁超声图像质量评估工具的开发与验证:POCUS IQ量表

Development and Validation of a Point-of-Care-Ultrasound Image Quality Assessment Tool: The POCUS IQ Scale.
PubMed 文献 · J Ultrasound Med · 2022-09-27

本研究开发了POCUS IQ量表,用于评估任何POCUS应用的图像采集技能,并以肺超声图像进行验证。通过专家与新手图像评分,量表显示良好的初步效度证据,评分者间信度中等,需至少1名评分者和2名患者达到良好心理测量信度。

要点

  • POCUS IQ量表可用于评估肺超声图像采集技能,专家评分中位数10.5/14,新手培训后12/14。
  • 量表内部一致性高(α=0.84,ω=0.91),但评分者间信度中等(Gwet's AC2=0.5)。
  • 决策研究建议至少1名评分者和2名患者以获得良好心理测量信度。
英文原文(摘要)· 点击展开

OBJECTIVES: We aimed to develop a standardized scoring tool to measure point-of-care ultrasound (POCUS) image quality and to determine validity evidence for its use to assess lung ultrasound image quality.

METHODS: The POCUS Image Quality (POCUS IQ) scale was developed by POCUS-trained physicians to assess sonographers' image acquisition skills by evaluating image quality for any POCUS application. The scale was piloted using lung images of healthy standardized patients acquired by three expert sonographers compared to three novices before and after training. All images (experts, novices pre-training, novices post-training) were scored on the POCUS IQ scale by three blinded POCUS-trained physicians. Reliability was assessed with fully-crossed generalizability and decision studies. Validity was assessed using Messick's framework.

RESULTS: Content validity was supported by the tool's development process of literature review, expert consensus, and pilot testing. Response process was supported by reviewer training and the blinded scoring process. Relation to other variables was supported by scores relating to sonographer experience: median expert score = 10.5/14 (IQR: 4), median novice pre-training score = 6/14 (IQR: 2.25), and novices' improvement after training (median post-training score = 12/14, IQR: 3.25). Internal structure was supported by internal consistency data (coefficient alpha = 0.84, omega coefficient = 0.91) and the generalizability study showing the main contributor to score variability was the sonographer (51%). The G-coefficient was 0.89, suggesting very good internal structure, however, Gwet's AC2 was 0.5, indicating moderate interrater reliability. The D study projected a minimum of 1 reviewer and 2 patients are needed for good psychometric reliability.

CONCLUSIONS: The POCUS scale has good preliminary validity evidence as an assessment tool for lung POCUS image acquisition skills. Further studies are needed to demonstrate its utility for other POCUS applications and as a feedback tool for POCUS learners.

来源:J Ultrasound Med,查看原文。版权归原作者所有。

引用

  1. Dessie, Calhoun, Kanjanauptom, et al. Development and Validation of a Point-of-Care-Ultrasound Image Quality Assessment Tool: The POCUS IQ Scale. J Ultrasound Med. 2022. PMID: 36165271. doi:10.1002/jum.16095

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。