文献速递神经胸部US

眼部超声测量视神经鞘直径对COPD急性发作的诊断准确性

Diagnostic Accuracy of Optic Nerve Sheath Diameter Measured With Ocular Ultrasonography in Acute Attack of Chronic Obstructive Pulmonary Disease.
PubMed 文献 · J Ultrasound Med · 2022-09-23

前瞻性研究纳入56例COPD急性发作患者与50名志愿者,用眼部超声线阵探头测量双眼视神经鞘直径。患者双眼ONSD均高于对照且治疗后回落;右眼ONSD在0.455切点下诊断COPD的敏感度68.1%、特异度75.7%。

要点

  • COPD急性发作患者双眼ONSD较对照升高,治疗后回落。
  • 右眼ONSD诊断COPD的AUC为0.727,切点0.455。
  • 左眼ONSD诊断COPD的AUC为0.718,切点0.505。

核心结论

  • 眼部超声测量ONSD可作为COPD急性发作伴症状患者的辅助诊断工具。

研究设计与样本

  • 前瞻性分析,纳入56例COPD急性发作患者与50名志愿者,COPD严重程度按mMRC呼吸困难量表评定,用眼部超声线阵探头测量双眼ONSD。

关键影像表现/征象

  • 患者左右眼ONSD均高于对照组(P = .017),治疗后ONSD回落(P = .021)。

诊断标准与关键数值

  • 右眼ONSD诊断COPD:切点0.455,敏感度68.1%,特异度75.7%,AUC 0.727(P = .0001,95%CI 0.609-0.833)。
  • 左眼ONSD诊断COPD:切点0.505,敏感度67%,特异度74.4%,AUC 0.718(P = .0001,95%CI 0.608-0.841)。

临床应用与阅片要点

  • 对COPD急性发作伴症状患者,可尝试用眼部超声测量ONSD辅助评估颅内压变化。
  • 测量时注意左右眼切点不同(右眼0.455、左眼0.505),报告需注明眼别与切点。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

OBJECTIVE: The study aimed to evaluate intracranial pressure changes by measuring ONSD before and after treatment in patients with chronic obstructive pulmonary disease (COPD).

METHODS: The study was designed as a prospective analysis, in which 56 COPD in acute exacerbation and 50 volunteers. COPD severity was determined by the Dyspnea Scale of Modified Medical Research Council (mMRC). Measurements were made with ocular ultrasonography and linear probe in both eyes.

RESULTS: Both the right and left ONSDs were higher in the patient compared to the control (P = .017) and regressed after the treatment (P = .021). In the ROC analysis for the predictability of COPD, right eye ONSDs showed a predictive potential for COPD with %75.7 specificity and %68.1 sensitivity at 0.455 cut-off (AUC: 0.727; P = .0001; %95CI: 0.609-0.833). Similar to the right eye, the left ONSD presented %74.4 specificity and %67 sensitivity at 0.505 cut-off value (AUC: 0.718; P = .0001; %95CI: 0.608-0.841).

CONCLUSION: The ONSD measurement that was with the help of ocular ultrasonography can be a useful diagnostic tool for symptomatic COPD presenting with an acute attack.

来源:J Ultrasound Med,查看原文。版权归原作者所有。