超微血管成像与超声造影评估颈动脉斑块新生血管的价值
本研究纳入45例患者共76个厚度≥2.0 mm的低回声颈动脉斑块,按厚度分组后分别行SMI和CEUS检查,采用0-3级半定量分级评估新生血管。两名超声医师应用两种方法的一致性高(Kappa 0.736和0.680),SMI与CEUS评估新生血管分级的一致性也高(Kappa 0.823和0.842),且两种方法的分级均与斑块厚度呈正相关。
要点
- SMI与CEUS评估颈动脉斑块新生血管分级的一致性高,Kappa值达0.823和0.842。
- SMI和CEUS的新生血管分级均与斑块厚度呈正相关,γ值0.735-0.805。
- 对于厚度≥2.0 mm的低回声斑块,SMI可替代CEUS评估新生血管。
关键影像表现/征象
- 斑块内新生血管在SMI上表现为血流信号,在CEUS上表现为增强信号,均按0-3级半定量分级评估。
- SMI与CEUS评估的新生血管分级均与斑块厚度呈正相关(医师A:γ=0.735和0.772;医师B:γ=0.805和0.798)。
诊断标准与关键数值
- 新生血管半定量分级标准:0级为斑块内无血流信号/无增强;1级为斑块内少量血流信号/增强;2级为斑块内中等量血流信号/增强;3级为斑块内丰富血流信号/增强。
- 两名医师应用SMI和CEUS诊断颈动脉斑块新生血管的一致性Kappa值分别为0.736和0.680。
- SMI与CEUS评估新生血管分级的一致性:医师A Kappa=0.823,医师B Kappa=0.842。
临床应用与阅片要点
- 对于厚度≥2.0 mm的低回声颈动脉斑块,可采用SMI评估新生血管,其结果与CEUS高度一致。
- 阅片时按0-3级半定量分级描述斑块内血流信号,注意斑块厚度对新生血管分级的影响。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To compare the consistency between superb microvascular imaging (SMI) and contrast-enhanced ultrasound (CEUS) for the detection of neovascularization in carotid plaques of different thicknesses and to evaluate the applied value of these two methods for detecting neovascularization in carotid plaques in the clinic.
METHODS: A total of 45 patients with carotid artery plaques who were diagnosed in our hospital involving 76 hypoechoic plaques with a thickness ≥2.0 mm were selected. According to thickness, the plaques were divided into three groups: 2.0-2.5 mm, 2.5-3.0 mm and ≥3.0 mm. Each group underwent both SMI and CEUS, and two experienced sonographers (A and B) analyzed the ultrasound images to evaluate the neovascularization of carotid plaques. The amount of the neovascular signal was assessed using a semi-quantitative grading scale (vascularity grade: grade 0-3). SMI and CEUS were graded respectively according to the visual methods as follows: grade 0: no blood flow signal/enhancement within plaques; grade 1: a few blood flow signals/enhancement within plaques; grade 2: medium blood flow signals/enhancement within plaques; and grade 3: extensive blood flow signals/enhancement within plaques. Kappa consistency test was used to analyze the consistency of the grade of neovascularization in plaques between SMI with CEUS. Gamma rank correlation analysis was used to examine the correlation between neovascularization grade by SMI and CEUS in plaque and plaque thickness.
RESULTS: Of these patients, 14 had unilateral plaques and 31 had bilateral plaques. The two sonographers were highly consistent in terms of applying SMI and CEUS methods for diagnosing neovascularization in carotid plaques (Kappa values were 0.736 and 0.680>0). Consistency was found between SMI and CEUS by sonographers (sonographer A: Kappa=0.823; sonographer B: Kappa=0.842) in evaluating the neovascular grade in the carotid plaques. SMI and CEUS grades were positively correlated with plaque thickness (sonographer A: γ = 0.735 and 0.772; sonographer B: γ = 0.805 and 0.798).
CONCLUSION: Neovascularization in carotid plaques was successfully detected by SMI in a manner that concurred well with CEUS results. Our data indicate that both CEUS and SMI have high diagnostic value for assessing the neovascularization of plaques.
引用
- Guo, Wang, Wang, et al. The Value of Superb Microvascular Imaging and Contrast-enhanced Ultrasound for the Evaluation of Neovascularization in Carotid Artery Plaques. Acad Radiol. 2022. PMID: 36123231. doi:10.1016/j.acra.2022.08.001
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。