文献速递骨肌儿科影像DR

深度学习测量双髂嵴高度差评估下肢不等长

Development and evaluation of deep-learning measurement of leg length discrepancy: bilateral iliac crest height difference measurement.
PubMed 文献 · Pediatr Radiol · 2022-09-19

本研究开发并评估基于双U-Net的深度学习算法,在儿童长骨X线片上通过双侧髂嵴高度差测量下肢不等长(LLD)。在300例回顾性影像中,算法成功勾画284例双侧髂嵴;模型辅助测量与人工测量均与参考标准显著相关,且模型辅助可大幅节省阅片时间。

要点

  • 深度学习可自动勾画双侧髂嵴并测量高度差,辅助人工测量可节省时间与人力。
  • 模型辅助测量与人工测量结果具有可比性,平均绝对误差小于单独模型测量。
  • 算法在300例中成功勾画284例双侧髂嵴,失败案例需人工复核。

关键影像表现/征象

  • 深度学习模型在300例中成功勾画284例双侧髂嵴。
  • 所有人工测量、深度学习模型及模型辅助方法均与参考标准测量显著相关,Pearson相关系数及组内相关系数(ICC)按此顺序降低。

诊断标准与关键数值

  • Pearson相关系数范围为0.880至0.996,ICC范围为0.914至0.997。
  • 人工测量、深度学习辅助模型及深度学习单独模型的平均绝对误差分别为0.7±0.6 mm、1.1±1.1 mm和2.3±5.2 mm。
  • 人工阅片平均耗时7小时12分钟,深度学习测量耗时7分钟26秒,放射科医生在深度学习模式下完成测量耗时74分钟。

临床应用与阅片要点

  • 模型单独测量误差较大(平均绝对误差2.3±5.2 mm),建议以模型辅助人工测量的工作模式用于日常报告。

局限性

  • 回顾性研究设计。
  • 算法在部分病例中未能成功勾画双侧髂嵴,可能影响自动测量的适用性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Leg length discrepancy (LLD) is a common problem that can cause long-term musculoskeletal problems. However, measuring LLD on radiography is time-consuming and labor intensive, despite being a simple task.

OBJECTIVE: To develop and evaluate a deep-learning algorithm for measurement of LLD on radiographs.

MATERIALS AND METHODS: In this Health Insurance Portability and Accountability Act (HIPAA)-compliant retrospective study, radiographs were obtained to develop a deep-learning algorithm. The algorithm developed with two U-Net models measures LLD using the difference between the bilateral iliac crest heights. For performance evaluation of the algorithm, 300 different radiographs were collected and LLD was measured by two radiologists, the algorithm alone and the model-assisting method. Statistical analysis was performed to compare the measurement differences with the measurement results of an experienced radiologist considered as the ground truth. The time spent on each measurement was then compared.

RESULTS: Of the 300 cases, the deep-learning model successfully delineated both iliac crests in 284. All human measurements, the deep-learning model and the model-assisting method, showed a significant correlation with ground truth measurements, while Pearson correlation coefficients and interclass correlations (ICCs) decreased in the order listed. (Pearson correlation coefficients ranged from 0.880 to 0.996 and ICCs ranged from 0.914 to 0.997.) The mean absolute errors of the human measurement, deep-learning-assisting model and deep-learning-alone model were 0.7 ± 0.6 mm, 1.1 ± 1.1 mm and 2.3 ± 5.2 mm, respectively. The reading time was 7 h and 12 min on average for human reading, while the deep-learning measurement took 7 min and 26 s. The radiologist took 74 min to complete measurements in the deep-learning mode.

CONCLUSION: A deep-learning U-Net model measuring the iliac crest height difference was possible on teleroentgenograms in children. LLD measurements assisted by the deep-learning algorithm saved time and labor while producing comparable results with human measurements.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Kim, Choi, Lee, et al. Development and evaluation of deep-learning measurement of leg length discrepancy: bilateral iliac crest height difference measurement. Pediatr Radiol. 2022. PMID: 36121497. doi:10.1007/s00247-022-05499-0

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。