文献速递乳腺甲状腺与浅表US

二维剪切波弹性成像评估乳腺癌预后因素

2D shear wave elastography in evaluation of prognostic factors in breast cancer.
PubMed 文献 · Radiol Med · 2022-09-19

前瞻性纳入44例B超可见乳腺肿块的女性患者,由两位不同经验操作者行定性和定量2D-SWE检查,评估重复性并分析其与临床病理参数的相关性。结果显示定性彩色图(κ=0.603)和定量E比值(ICC=0.771)重复性良好,E比值与Elston-Ellis分级显著相关(P<0.030),提示2D-SWE有望用于评估部分预后因素。

要点

  • 2D-SWE定性彩色图和定量E比值在不同经验操作者间重复性良好。
  • E比值与Elston-Ellis组织学分级显著相关,或可辅助评估预后。
  • 肿瘤大小也与Elston-Ellis分级显著相关,阅片时需结合分析。

关键影像表现/征象

  • 所有患者B超均可见肿块,随后接受定性和定量2D-SWE评估。
  • 定性彩色图评估的观察者间一致性良好(Cohen's kappa=0.603)。
  • 定量E比值的观察者间重复性良好(ICC=0.771)。

诊断标准与关键数值

  • 定性彩色图观察者间一致性Cohen's kappa=0.603。
  • 定量E比值观察者间组内相关系数ICC=0.771。
  • E比值与Elston-Ellis分级显著相关(P<0.030)。
  • 肿瘤大小与Elston-Ellis分级显著相关(P<0.041)。

临床应用与阅片要点

  • 日常阅片可尝试用2D-SWE的E比值辅助评估组织学分级较高的乳腺癌。
  • 定性彩色图和定量E比值均可用于不同经验操作者间的重复性评估。

局限性

  • 样本量较小(44例),为单中心前瞻性研究。
  • 仅纳入B超可见肿块的乳腺癌患者,结论外推需谨慎。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate the reproducibility of the 2D shear wave elastography (2D-SWE) method and to identify the prognostic factors of breast lesions.

METHODS: In this prospective study, 44 female patients were consecutively included from January 2020 to September 2021. All patients showing visible masses at B-mode ultrasound underwent to clinical evaluation, followed by qualitative and quantitative 2D-SWE by two different operators with over 15-year and 2-year experience, respectively. Subsequently, patients underwent to surgical treatment after core needle biopsy. Reproducibility of qualitative and quantitative 2D-SWE was evaluated by Cohen's kappa and intraclass correlation coefficient (ICC). Clinical, imaging, and histopathological data and 2D-SWE evaluations were analysed with Spearman's rank correlation test.

RESULTS: The mean age of the patients was 55 years ± 12. The mean histological and ultrasound tumour size of were 23.1 mm ± 13.2 and 17.2 mm ± 10.2, respectively. The interobserver agreement showed a good reproducibility limited to the qualitative evaluation colour maps (Cohen's kappa = 0.603) and to the quantitative evaluation E ratio (ICC = 0.771). Correlation analysis between the ultrasound and 2D-SWE values and the clinical-pathological parameters showed a significant relationship between E ratio and Elston-Ellis grading (P < 0.030) and between tumour size and Elston-Ellis grading (P < 0.041).

CONCLUSION: The 2D-SWE has shown good reproducibility among operators with different experience. It could be a promising tool in the evaluation of some prognostic factors in ultrasound visible breast cancer.

来源:Radiol Med,查看原文。版权归原作者所有。

引用

  1. Ventura, Baldassarre, Cerimele, et al. 2D shear wave elastography in evaluation of prognostic factors in breast cancer. Radiol Med. 2022. PMID: 36123521. doi:10.1007/s11547-022-01559-5