指南与共识心血管CT

CAD-RADS™ 2.0:2022年冠状动脉疾病报告与数据系统专家共识

CAD-RADS™ 2.0 - 2022 Coronary Artery Disease-Reporting and Data System: An Expert Consensus Document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Cardiology (ACC), the American College of Radiology (ACR), and the North America Society of Cardiovascular Imaging (NASCI).
指南 / 共识 · JACC Cardiovasc Imaging · 2022-09-14

该2022年更新版CAD-RADS 2.0由SCCT、ACC、ACR和NASCI联合发布,旨在改进冠状动脉CT血管成像(CCTA)的初始报告系统,纳入心脏CT新技术进展、近期临床试验数据和新的临床指南。更新后的分类沿用狭窄、斑块负荷和修饰符的框架,包括在可行时使用CT血流储备分数(CT-FFR)或心肌CT灌注(CTP)评估病变特异性缺血,并新增P1至P4斑块负荷描述符。

要点

  • 狭窄 severity 分类以患者为单位,取最严重冠状动脉管腔狭窄,从CAD-RADS 0(无斑块或狭窄)到CAD-RADS 5(至少一支冠状动脉完全闭塞)。
  • 新增P1至P4描述符用于表示斑块负荷递增类别,并推荐多种方法估计和报告总斑块负荷。
  • 可行时使用CT-FFR或CTP评估病变特异性缺血,作为修饰符纳入报告框架。

核心结论

  • CAD-RADS 2.0旨在通过标准化CCTA报告框架,促进检查结果与转诊医师的沟通,并提供后续患者管理建议。

诊断标准与关键数值

  • 狭窄 severity 分类以患者为单位,取最严重冠状动脉管腔狭窄,范围从CAD-RADS 0(无斑块或狭窄)到CAD-RADS 5(至少一支冠状动脉完全闭塞)。
  • 新增P1至P4描述符用于表示斑块负荷递增类别。
  • 可行时使用CT-FFR或CTP评估病变特异性缺血,作为修饰符纳入分类框架。

临床应用与阅片要点

  • 报告时应将CAD-RADS分类与报告中的印象一起解读,以促进与转诊医师的沟通并提供后续管理建议。
  • 应评估并报告总斑块负荷,使用P1至P4描述符表示递增类别。
  • 在可行时,应使用CT-FFR或CTP评估病变特异性缺血并纳入报告。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Coronary Artery Disease Reporting and Data System (CAD-RADS) was created to standardize reporting system for patients undergoing coronary CT angiography (CCTA) and to guide possible next steps in patient management. The goal of this updated 2022 CAD-RADS 2.0 is to improve the initial reporting system for CCTA by considering new technical developments in cardiac CT, including data from recent clinical trials and new clinical guidelines. The updated CAD-RADS classification will follow an established framework of stenosis, plaque burden, and modifiers, which will include assessment of lesion-specific ischemia using CT fractional-flow-reserve (CT-FFR) or myocardial CT perfusion (CTP), when performed. Similar to the method used in the original CAD-RADS version, the determinant for stenosis severity classification will be the most severe coronary artery luminal stenosis on a per-patient basis, ranging from CAD-RADS 0 (zero) for absence of any plaque or stenosis to CAD-RADS 5 indicating the presence of at least one totally occluded coronary artery. Given the increasing data supporting the prognostic relevance of coronary plaque burden, this document will provide various methods to estimate and report total plaque burden. The addition of P1 to P4 descriptors are used to denote increasing categories of plaque burden. The main goal of CAD-RADS, which should always be interpreted together with the impression found in the report, remains to facilitate communication of test results with referring physicians along with suggestions for subsequent patient management. In addition, CAD-RADS will continue to provide a framework of standardization that may benefit education, research, peer-review, artificial intelligence development, clinical trial design, population health and quality assurance with the ultimate goal of improving patient care.

来源:JACC Cardiovasc Imaging,查看原文。版权归原作者所有。

引用

  1. Cury, Leipsic, Abbara, et al. CAD-RADS™ 2.0 - 2022 Coronary Artery Disease-Reporting and Data System: An Expert Consensus Document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Cardiology (ACC), the American College of Radiology (ACR), and the North America Society of Cardiovascular Imaging (NASCI). JACC Cardiovasc Imaging. 2022. PMID: 36115815. doi:10.1016/j.jcmg.2022.07.002

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。