指南与共识心血管CT

CAD-RADS 2.0:2022 冠状动脉疾病报告与数据系统专家共识

CAD-RADS 2.0 - 2022 Coronary Artery Disease-Reporting and Data System: An Expert Consensus Document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Cardiology (ACC), the American College of Radiology (ACR), and the North America Society of Cardiovascular Imaging
RSS 订阅 · 指南共识 · 心血管影像 · 2022-09-17

共识仍以患者水平最严重冠状动脉管腔狭窄程度分级(CAD-RADS 0–5),新增斑块负荷 P1–P4 描述符,并纳入 CT-FFR 或心肌 CT 灌注评估 lesion-specific ischemia 的修饰符,以标准化 CCTA 报告并指导后续管理。

要点

  • stenosis 分级以患者水平最严重管腔狭窄为准,从 CAD-RADS 0 到 5。
  • 新增 P1–P4 斑块负荷描述符,用于报告总体斑块负荷。
  • 若行 CT-FFR 或 CTP,可加用评估 lesion-specific ischemia 的修饰符。

核心结论

  • CAD-RADS 2.0 旨在通过纳入心脏 CT 新技术、近期临床试验数据与新临床指南,改进 CCTA 初始报告系统。
  • CAD-RADS 分类沿用狭窄、斑块负荷与修饰符的框架,并纳入 CT-FFR 或 CTP 评估 lesion-specific ischemia。
  • CAD-RADS 应始终结合报告中的 impression 解读,以促进与转诊医生的沟通并给出后续管理建议。

研究设计与样本

  • 本文为 SCCT、ACC、ACR 与 NASCI 联合发布的专家共识文件。
  • 共识基于近期临床试验数据与新临床指南对 2022 版 CAD-RADS 进行更新。
  • 分类框架包括狭窄程度、斑块负荷与修饰符,并在行 CT-FFR 或 CTP 时纳入 lesion-specific ischemia 评估。

诊断标准与关键数值

  • 狭窄严重程度分级以患者水平最严重冠状动脉管腔狭窄为决定因素,范围从 CAD-RADS 0(无任何斑块或狭窄)到 CAD-RADS 5(至少一支冠状动脉完全闭塞)。
  • 斑块负荷采用 P1 至 P4 描述符表示斑块负荷的递增类别。
  • 若行 CT-FFR 或 CTP,可加用评估 lesion-specific ischemia 的修饰符。

临床应用与阅片要点

  • 报告 CCTA 时应以患者水平最严重管腔狭窄确定 CAD-RADS 分级,并同时报告总体斑块负荷 P1–P4。
  • 若进行了 CT-FFR 或 CTP,应在报告中体现 lesion-specific ischemia 评估结果作为修饰符。
  • CAD-RADS 分级须与报告 impression 结合解读,并向转诊医生给出后续管理建议。
英文原文(摘要)· 点击展开

JACC Cardiovasc Imaging. 2022 Nov;15(11):1974-2001. doi: 10.1016/j.jcmg.2022.07.002. Epub 2022 Sep 14. ABSTRACT Coronary Artery Disease Reporting and Data System (CAD-RADS) was created to standardize reporting system for patients undergoing coronary CT angiography (CCTA) and to guide possible next steps in patient management. The goal of this updated 2022 CAD-RADS 2.0 is to improve the initial reporting system for CCTA by considering new technical developments in cardiac CT, including data from recent clinical trials and new clinical guidelines. The updated CAD-RADS classification will follow an established framework of stenosis, plaque burden, and modifiers, which will include assessment of lesion-specific ischemia using CT fractional-flow-reserve (CT-FFR) or myocardial CT perfusion (CTP), when performed. Similar to the method used in the original CAD-RADS version, the determinant for stenosis severity classification will be the most severe coronary artery luminal stenosis on a per-patient basis, ranging from CAD-RADS 0 (zero) for absence of any plaque or stenosis to CAD-RADS 5 indicating the presence of at least one totally occluded coronary artery. Given the increasing data supporting the prognostic relevance of coronary plaque burden, this document will provide various methods to estimate and report total plaque burden. The addition of P1 to P4 descriptors are used to denote increasing categories of plaque burden. The main goal of CAD-RADS, which should always be interpreted together with the impression found in the report, remains to facilitate communication of test results with referring physicians along with suggestions for subsequent patient management. In addition, CAD-RADS will continue to provide a framework of standardization that may benefit education, research, peer-review, artificial intelligence development, clinical trial design, population health and quality assurance with the ultimate goal of improving patient care. PMID: 36115815 | DOI: 10.1016/j.jcmg.2022.07.002

来源:指南共识 · 心血管影像,查看原文。版权归原作者所有。

引用

  1. 指南共识 · 心血管影像:CAD-RADS 2.0 - 2022 Coronary Artery Disease-Reporting and Data System: An Expert Consensus Document of the Society of Cardiovascular Computed Tomography (SCCT), the American College of Cardiology (ACC), the American College of Radiology (ACR), and the North America Society of Cardiovascular Imaging (NASCI)

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。