VI-RADS 诊断肌层浸润性膀胱癌的阅片者间信度:系统评价与 meta 分析
该系统评价与 meta 分析纳入 19 项研究、2439 例受试者,评估 VI-RADS 术前检测肌层浸润性膀胱癌的阅片者间一致性。合并阅片者间信度为 κ=0.76(95%CI 0.73-0.80),各研究范围为 κ 0.45-0.96,提示不同经验水平的放射科医生间具有较高一致性,支持 VI-RADS 用于常规临床分期。
要点
- VI-RADS 检测 MIBC 的合并阅片者间信度 κ=0.76,属较高一致性。
- 各研究间 κ 范围 0.45-0.96,异质性高(I2=92.13%)。
- 异质性来源包括磁场强度、T2WI 层厚、阅片者数量及研究中心数等。
核心结论
- VI-RADS 对肌层浸润性膀胱癌的判读在不同经验放射科医生间具有较高阅片者间信度,合并 κ=0.76(95%CI 0.73-0.80)。
研究设计与样本
- 纳入 19 项合格研究,共 2439 例受试者,排除病例报告、综述、社论及数据不足的研究。
- 采用诊断信度质量评价清单评估偏倚风险,以 Cohen kappa 系数评估一致性,用亚组分析和 meta 回归探索异质性。
诊断标准与关键数值
- VI-RADS 检测 MIBC 的合并阅片者间信度为 κ=0.76(95%CI 0.73-0.80;I2=92.13%,Q(50)=635.08,p<0.01)。
- 纳入研究中 VI-RADS 检测 MIBC 的阅片者间一致性范围为 κ 0.45 至 0.96。
临床应用与阅片要点
- VI-RADS 阅片者间一致性较高,支持将其用于膀胱癌术前分期的常规临床实践。
- 不同经验水平的放射科医生均可应用 VI-RADS 判读,但需注意研究间异质性较高。
局限性
- 研究间异质性高(I2=92.13%),异质性来源包括磁场强度、T2WI 层厚、阅片者数量、样本量、研究设计、中心数、发表年份、男性患者比例和平均年龄。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
To evaluate the diagnostic agreement between readers in VI-RADS interpretation to detect muscle-invasive bladder cancer (MIBC) preoperatively, we conducted a systematic review and meta-analysis of the available data. Scopus, PubMed, Web of Science, and Embase databases were systematically searched up to November 13, 2021. Case reports, review articles, editorials, and studies with insufficient data were eliminated. The Quality Appraisal of the Diagnostic Reliability Checklist was used to assess the risk of bias. The degree of agreement was determined by Cohen's kappa coefficient (κ) for comparison of data. The heterogeneity of these studies was explored using subgroup analysis and meta-regression analysis. The level of confidence was set at 0.05. All analyses were conducted in STATA 16.0. Overall, 19 eligible studies, consisting of 2439 participants, were included in this meta-analysis. The inter-reader agreement for VI-RADS in MIBC detection ranged from κ of 0.45 to 0.96 among included studies. The pooled inter-reader reliability was calculated as 0.76 [95% CI 0.73-0.80; I2 = 92.13%, Q(50) = 635.08, p < 0.01]. Sources of heterogeneity included magnetic strength, T2WI slice thickness, number of readers, sample size, study design, number of centers, year of publication, proportion of male patients, and mean age. There is substantial reliability in VI-RADS interpretation for MIBC among radiologists with various levels of expertise. The high degree of inter-reader agreement for MIBC detection supports the implementation of VI-RADS in routine clinical practice for the staging paradigm of bladder cancer.
引用
- Jazayeri, Dehghanbanadaki, Hosseini, et al. Inter-reader reliability of the vesical imaging-reporting and data system (VI-RADS) for muscle-invasive bladder cancer: a systematic review and meta-analysis. Abdom Radiol (NY). 2022. PMID: 36112202. doi:10.1007/s00261-022-03669-0
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。