3D双反转恢复序列与3D液体衰减反转恢复序列在急性视神经炎精准诊断中的对比
本研究纳入视觉诱发电位异常的急性视神经炎病例与对照,比较3D FLAIR与3D DIR诊断急性视神经炎的准确性。结果显示3D DIR在预测视神经炎时各节段ROC曲线下面积均更大(0.8 vs 0.623),信号强度比的AUC也更高(0.844 vs 0.704),提示3D DIR诊断准确性更优。
要点
- 3D DIR在眶内段检测异常的优势比最高(OR 3.64,P<0.001)。
- 3D DIR各节段ROC曲线下面积均大于3D FLAIR(0.8 vs 0.623,P<0.001)。
- 3D DIR信号强度比AUC高于3D FLAIR(0.844 vs 0.704,P=0.004)。
核心结论
- 3D DIR凭借其独特对比生成机制,在急性视神经炎病变诊断中比3D FLAIR具有更高的诊断准确性和诊断信心。
研究设计与样本
- 研究为病例对照设计,纳入视觉诱发电位异常的急性视神经炎病例并与对照比较,成像方案在常规序列基础上加入3D FLAIR和3D DIR。
- 由两名经验丰富的神经放射科医生评估视神经信号,比较序列间一致性、优势比、ROC曲线、信号强度比及观察者间一致性。
关键影像表现/征象
- 视神经信号按眶内段、交叉前段和视交叉段三个节段评估高信号。
- 在Likert量表上,交叉前段序列间一致性良好(ICC 0.748,p<0.001);二分类分析中交叉前段Kappa最高(0.525,p<0.001)。
诊断标准与关键数值
- 3D DIR预测视神经炎在眶内段的优势比最高(OR 3.64,P<0.001),FLAIR在视交叉段优势比最高(OR 2.25,P=0.007)。
- 3D DIR各节段ROC曲线下面积均大于3D FLAIR(0.8 vs 0.623,p<0.001),信号强度比AUC更高(0.844 vs 0.704,p=0.004)。
临床应用与阅片要点
- 在急性视神经炎评估中,3D DIR对眶内段病变检测优势明显,可优先用于该节段。
- 3D FLAIR在视交叉段预测视神经炎的优势比更高,阅片时需结合节段选择序列。
- 序列间在交叉前段一致性良好,但二分类Kappa仅中等,报告时应结合多序列综合判断。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
BACKGROUND: The small size, intraorbital fat, perioptic CSF sheath and air-bone interface pose challenges to optic nerve imaging in cases of acute optic neuritis. The study is intended to compare the diagnostic accuracy of 3-dimensional Fluid Attenuation Inversion Recovery (3D FLAIR) and 3-dimensional Double Inversion Recovery (3D DIR) in cases of acute optic neuritis (AON).
METHODS: Cases of AON with visual evoked potentials (VEP) abnormality were recruited and compared with controls. Imaging protocol incorporated 3D FLAIR and 3D DIR to routine sequences. The optic nerve signal was evaluated for hyperintensity across three segments viz, intraorbital, prechiasmatic, and optic-chiasm segments. The inter-modality agreement, odds ratio, receiver operator characteristics (ROC) curve, Signal intensity ratio (SIR) and interobserver agreement (between two experienced neuroradiologists) was compared between the sequences.
RESULTS: Good Intermodality agreement (IMA) was found in the PC segment (ICC: 0.748, p < 0.001) in the Likert scale. In a binary scale of analysis (signal Normal vs abnormal) Kappa was highest for the PC segment (0.525, p < 0.001). The 3D-DIR sequence had an overall higher odds ratio (OR) of detecting abnormality compared to 3D-FLAIR. OR was highest for 3D DIR in the Orbital segment (OR: 3.64, P-value < 0.001) and for FLAIR in the chiasmal segment (OR 2.25, P = 0.007) for predicting optic neuritis. The area under the ROC curve for 3-D DIR was larger across all the segments (0.8 vs 0.623, p < 0.001). The Area under ROC for signal intensity ratio was higher for 3D-DIR(0.844 vs 0.704, p = 0.004) CONCLUSION: 3D DIR, under its unique contrast-generating scheme, demonstrates a greater diagnostic accuracy and offers confidence in the diagnosis of AON lesions when compared to 3D FLAIR.
引用
- Murumkar, Priyadarshini Baishya, Kulanthaivelu, et al. Comparison of 3D Double Inversion Recovery (DIR) versus 3D Fluid Attenuated Inversion Recovery (FLAIR) in precise diagnosis of acute optic neuritis. Eur J Radiol. 2022. PMID: 36113286. doi:10.1016/j.ejrad.2022.110505
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。