光子计数探测器CT提升腹部动脉期图像质量:与能量积分CT的头对头比较

Photon-counting detector CT improves quality of arterial phase abdominal scans: A head-to-head comparison with energy-integrating CT.
PubMed 文献 · Eur J Radiol · 2022-09-10

本研究纳入84例同时接受PCD-CT和EID-CT腹部扫描的患者,比较动脉期图像质量。PCD-CT的CT剂量指数和有效剂量分别降低18%和26%,低keV虚拟单能图像在客观噪声、CNR及主观图像质量、病灶清晰度上均优于EID-CT。

要点

  • PCD-CT低keV(50–60 keV)VMI可显著提升腹部动脉期图像质量和病灶清晰度。
  • PCD-CT在降低辐射剂量的同时(CTDI降18%,有效剂量降26%)仍保持更优图像质量。
  • 高于70 keV的VMI病灶清晰度反而下降,阅片时应优先选择低keV重建。

关键影像表现/征象

  • PCD-CT的低keV VMI(≤60 keV)和多能T3D图像中,肾皮质及血管对肝实质的CNR显著高于EID-CT(p < 0.004)。
  • PCD-CT 50和60 keV VMI的整体图像质量评分显著优于EID-CT(p < 0.01),评价者间一致性alpha = 0.80。
  • 低keV VMI的病灶清晰度显著更好(p < 0.03),而>70 keV VMI的病灶清晰度更差。

诊断标准与关键数值

  • PCD-CT的CT剂量指数和有效剂量分别比EID-CT低18%和26%。
  • 主观图像质量采用5点Likert量表评估噪声、对比度、病灶清晰度和整体图像质量。

临床应用与阅片要点

  • 腹部动脉期肿瘤扫描可优先选择PCD-CT低keV(50–60 keV)VMI或多能T3D图像,以提升血管和富血供病灶的对比。
  • 避免使用>70 keV的VMI评价病灶清晰度,因其清晰度评分反而下降。
  • PCD-CT可在降低辐射剂量的同时维持或提升图像质量,适合需要多次随访的肿瘤患者。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: Photon-counting detector (PCD)-CT is expected to have a substantial impact on oncologic abdominal imaging. We compared subjective and objective image quality between PCD-CT and conventional energy-integrating detector (EID-)CT arterial phase abdominal scans.

METHODS: This study included 84 patients undergoing both types of abdominal CT. EID-CT scans were acquired with a tube voltage of 100 kVp. With PCD-CT, acquired with 120-kVp, we reconstructed polychromatic T3D images and virtual monoenergetic images (VMIs) in 10-keV intervals from 40 to 90 keV. Quantitative image analysis included noise and contrast-to-noise ratio (CNR) of hepatic vessels, kidney cortex, and hypervascular liver lesions to liver parenchyma. Three raters used a 5-point Likert scale for qualitative image analysis of image noise and contrast, lesion conspicuity, and overall image quality. Radiation dose exposure (CT dose index) was compared between the two CT types.

RESULTS: Mean CT dose index and effective dose were respectively 18 % and 26 % lower with PCD-CT versus EID-CT. Compared with EID-CT, CNRs of kidney cortex and vessel to liver parenchyma were significantly higher in PCD-CT VMIs at energies ≤ 60 keV and in polychromatic T3D images (p < 0.004). Overall image quality of PCD-CT VMIs at 50 and 60 keV was rated as significantly better (p < 0.01) than the EID-CT images (inter-reader agreement alpha = 0.80). Lesion conspicuity was significantly better in low-keV VMIs (p < 0.03) and worse in > 70-keV VMIs.

CONCLUSIONS: With low-keV VMI, PCD-CT yields significantly improved objective and subjective quality of arterial phase oncological imaging compared with EID-CT. This advantage may translate into higher diagnostic confidence and lower radiation dose protocols.

来源:Eur J Radiol,查看原文。版权归原作者所有。