超声引导下粗针活检对甲状腺切除床病变的诊断效能
本研究纳入124个甲状腺切除床病变,评估超声引导下粗针活检(CNB)的诊断效能与安全性。CNB标本均满足病理分析,诊断恶性病变的敏感度98.0%、特异度100%、阳性预测值100%、阴性预测值98.6%,无并发症发生。CNB对甲状腺切除床病变的鉴别诊断准确且安全。
要点
- CNB对甲状腺切除床恶性病变诊断敏感度98.0%、特异度100%。
- CNB标本均满足病理分析,仅1.6%结果不确定。
- CNB可明确既往FNA结果不确定的病变。
关键影像表现/征象
- 甲状腺切除床病变常表现为可疑超声特征,但FNA可能无法提供明确病理信息。
- CNB病理显示良性病变包括非缝线肉芽肿的良性术后病变(32.3%,40/124)、缝线肉芽肿(15.3%,19/124)、残留甲状腺组织(5.6%,7/124)、甲状旁腺病变(4%,5/124)和脓肿(1.6%,2/124)。
诊断标准与关键数值
- CNB诊断恶性甲状腺切除床病变(122个可评估病变)的敏感度为98.0%(49/50),特异度为100%(72/72),阳性预测值为100%(49/49),阴性预测值为98.6%(72/73)。
- 所有CNB样本(100%)满足病理分析,2个病变(1.6%)病理结果不确定。
- 11个病变因既往FNA结果不确定而转行CNB,CNB均获得正确的明确病理诊断。
临床应用与阅片要点
- 对甲状腺切除床可疑病变,CNB可提供明确病理诊断,尤其适用于FNA结果不确定者。
- CNB可鉴别复发与缝线肉芽肿、残留甲状腺组织、甲状旁腺病变等良性术后改变。
- CNB操作安全,未见主要或次要并发症。
局限性
- 回顾性研究设计。
- 样本来自单中心,可能存在选择偏倚。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: Thyroidectomy bed lesions frequently show suspicious ultrasound (US) features after thyroid surgery. Fine-needle aspiration (FNA) may not provide definitive pathological information about the lesions. Although core-needle biopsy (CNB) has excellent diagnostic performance in characterizing suspicious thyroid nodules, no published studies have evaluated the performance of CNB specifically for thyroidectomy bed lesions. Therefore, we aimed to evaluate the diagnostic performance and safety of CNB for characterizing thyroidectomy bed lesions.
MATERIALS AND METHODS: A total of 124 thyroidectomy bed lesions in 113 patients (79 female and 34 male; age, 23-85 years) who underwent US-guided CNB between December 2008 and December 2020 were included. We reviewed the US imaging features of the target lesions and the histories of previous biopsies. The pathologic results, diagnostic performance for malignancy, and complications of CNB were analyzed.
RESULTS: All samples (100%) obtained by CNB were adequate for pathological analysis. Pathological analysis revealed inconclusive results in two lesions (1.6%). According to the reference standard, 50 lesions were ultimately malignant (40.3%), and 72 were benign (58.1%), excluding the two inconclusive lesions. The performance of CNB for diagnosing malignant thyroidectomy bed lesions in the 122 lesions had a sensitivity of 98.0% (49/50), a specificity of 100% (72/72), positive predictive value of 100% (49/49), and negative predictive value of 98.6% (72/73). Eleven lesions were referred for CNB after prior inconclusive FNA results in thyroidectomy bed lesions, for all of which CNB yielded correct conclusive pathologic diagnoses. According to the pathological analysis of CNB, there were various benign lesions (58.9%, 73/124) besides recurrence, including benign postoperative lesions other than suture granuloma (32.3%, 40/124), suture granuloma (15.3%, 19/124), remnant thyroid tissue (5.6%, 7/124), parathyroid lesions (4%, 5/124), and abscesses (1.6%, 2/124). No major or minor complications were associated with the CNB procedure.
CONCLUSION: US-guided CNB is accurate and safe for characterizing thyroidectomy bed lesions.
引用
- Jeong, Baek, Chung, et al. Diagnostic Performance of Core Needle Biopsy for Characterizing Thyroidectomy Bed Lesions. Korean J Radiol. 2022. PMID: 36098339. doi:10.3348/kjr.2021.0772
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。