非心电门控低剂量胸部CT全自动冠状动脉钙化评分:与心电门控心脏CT的比较
本回顾性多中心研究纳入452例同时接受心电门控钙化评分CT和低剂量胸部CT的受试者,以手动CAC评分为参考标准,验证基于AI的全自动CAC评分系统。结果显示自动评分在CSCT和LDCT上均与手动评分高度一致(ICC 0.998和0.989),但LDCT上严重程度分级的可靠性在不同机构间存在异质性。
要点
- AI自动CAC评分在LDCT上与手动评分一致性良好,可用于机会性筛查。
- LDCT自动评分的严重程度分级可靠性在不同数据集间存在差异。
- LDCT自动评分假阳性率高于CSCT,主要原因为图像噪声和伪影。
关键影像表现/征象
- 自动CAC评分在CSCT和LDCT上均与手动评分高度一致,ICC分别为0.998(95%CI 0.998-0.999)和0.989(95%CI 0.987-0.991)。
- 自动评分与手动评分的平均差异及95%一致性界限在CSCT为1.3 ± 37.1,在LDCT为0.8 ± 75.7。
- 自动评分对CAC严重程度分级的可靠性在CSCT上优秀(κ=0.918-0.972),在LDCT上良好至优秀但数据集间异质(κ=0.748-0.924)。
- LDCT自动评分假阳性率高于CSCT自动评分,两者最常见假阳性原因均为图像噪声和伪影。
诊断标准与关键数值
- 以手动CAC评分为参考标准,自动CAC评分在CSCT上的ICC为0.998(95%CI 0.998-0.999),在LDCT上为0.989(95%CI 0.987-0.991)。
- CAC严重程度分级的加权kappa在CSCT上为0.918-0.972,在LDCT上为0.748-0.924。
临床应用与阅片要点
- LDCT上可应用AI自动CAC评分进行机会性心血管风险筛查,但需注意机构间可靠性差异。
- 报告LDCT自动CAC评分时应警惕图像噪声和伪影导致的假阳性,必要时结合手动复核。
局限性
- 回顾性研究设计。
- LDCT自动评分严重程度分级的可靠性在不同机构间存在异质性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To validate an artificial intelligence (AI)-based fully automatic coronary artery calcium (CAC) scoring system on non-electrocardiogram (ECG)-gated low-dose chest computed tomography (LDCT) using multi-institutional datasets with manual CAC scoring as the reference standard.
METHODS: This retrospective study included 452 subjects from three academic institutions, who underwent both ECG-gated calcium scoring computed tomography (CSCT) and LDCT scans. For all CSCT and LDCT scans, automatic CAC scoring (CAC_auto) was performed using AI-based software, and manual CAC scoring (CAC_man) was set as the reference standard. The reliability and agreement of CAC_auto was evaluated and compared with that of CAC_man using intraclass correlation coefficients (ICCs) and Bland-Altman plots. The reliability between CAC_auto and CAC_man for CAC severity categories was analyzed using weighted kappa (κ) statistics.
RESULTS: CAC_auto on CSCT and LDCT yielded a high ICC (0.998, 95% confidence interval (CI) 0.998-0.999 and 0.989, 95% CI 0.987-0.991, respectively) and a mean difference with 95% limits of agreement of 1.3 ± 37.1 and 0.8 ± 75.7, respectively. CAC_auto achieved excellent reliability for CAC severity (κ = 0.918-0.972) on CSCT and good to excellent but heterogenous reliability among datasets (κ = 0.748-0.924) on LDCT.
CONCLUSIONS: The application of an AI-based automatic CAC scoring software to LDCT shows good to excellent reliability in CAC score and CAC severity categorization in multi-institutional datasets; however, the reliability varies among institutions.
KEY POINTS: • AI-based automatic CAC scoring on LDCT shows excellent reliability with manual CAC scoring in multi-institutional datasets. • The reliability for CAC score-based severity categorization varies among datasets. • Automatic scoring for LDCT shows a higher false-positive rate than automatic scoring for CSCT, and most common causes of a false-positive are image noise and artifacts for both CSCT and LDCT.
引用
- Suh, Kim, Lee, et al. Fully automatic coronary calcium scoring in non-ECG-gated low-dose chest CT: comparison with ECG-gated cardiac CT. Eur Radiol. 2022. PMID: 36098798. doi:10.1007/s00330-022-09117-3
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。