文献速递胸部MRCT

低场0.55T MRI评估肺磨玻璃及纤维化样影:阅片者间与模态间一致性

Low-field 0.55 T MRI for assessment of pulmonary groundglass and fibrosis-like opacities: Inter-reader and inter-modality concordance.
PubMed 文献 · Eur J Radiol · 2022-09-08

研究纳入64例新冠后患者,共106次非增强0.55T心肺MRI,其中20例22次MRI有30天内临床胸部CT对照。两位胸部放射科医师按肺象限评分磨玻璃及纤维化样影,结果显示MRI阅片者间一致性 fair 至 moderate,与CT的模态间一致性 moderate 至 substantial。

要点

  • 0.55T非增强MRI可检测肺磨玻璃及纤维化样影,但与CT一致性中等。
  • MRI阅片者间一致性低于CT,尤其对病变范围评分一致性较差。
  • 亚胸膜线及网状影的模态间一致性较好(k=0.80),但磨玻璃影存在一致性一般(k=0.43)。

关键影像表现/征象

  • MRI可评估肺磨玻璃影及纤维化样亚胸膜网状影和亚胸膜线。
  • CT上病变存在、范围、分布及亚胸膜线/网状影的阅片者间一致率分别为99%、78%、97%、99%、94%。
  • MRI上相应一致率分别为85%、48%、70%、86%、76%。

诊断标准与关键数值

  • CT阅片者间kappa:病变存在0.96、范围0.86、分布0.94、亚胸膜线0.97、网状影0.89。
  • MRI阅片者间kappa:病变存在0.57、范围0.32、分布0.46、亚胸膜线0.47、网状影0.37。
  • CT与MRI模态间一致率:病变存在86%、范围52%、分布79%、亚胸膜线93%、网状影76%;对应kappa分别为0.43、0.63、0.65、0.80、0.52。

临床应用与阅片要点

  • 0.55T MRI可作为无辐射评估肺磨玻璃及纤维化样影的替代手段,但需注意其与CT的一致性中等,尤其磨玻璃影存在判断。
  • 对病变范围评分MRI一致性较低(k=0.32),报告时应谨慎描述范围。
  • 亚胸膜线及网状影在MRI与CT间一致性较好(k=0.80),可较可靠识别。

局限性

  • 仅20例22次MRI有对应CT,模态间比较样本量小。
  • 单中心回顾性研究,可能存在选择偏倚。
  • MRI阅片者间一致性较低,可能影响结果稳定性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

PURPOSE: To evaluate detection and characterization of groundglass and fibrosis-like opacities imaged by non-contrast 0.55 Tesla MRI, and versus clinically-acquired chest CT images, in a cohort of post-Covid patients.

MATERIALS AND METHODS: 64 individuals (26 women, mean age 53 ± 14 years, range 19-85) with history of Covid-19 pneumonia were recruited through a survivorship registry, with 106 non-contrast low-field 0.55 T cardiopulmonary MRI exams acquired from 9/8/2020-9/28/2021. MRI exams were obtained at an average interval of 9.5 ± 4.5 months from initial symptom report (range 1-18 months). Of these, 20 participants with 22 MRI exams had corresponding clinically-acquired CT chest imaging obtained within 30 days of MRI (average interval 18 ± 9 days, range 0-30). MR and CT images were reviewed and scored by two thoracic radiologists, for presence and extent of lung opacity by quadrant, opacity distribution, and presence versus absence of fibrosis-like subpleural reticulation and subpleural lines. Scoring was performed for each of four lung quadrants: right upper and middle lobe, right lower lobe, left upper lobe and lingula, and left lower lobe. Agreement between readers and modalities was assessed with simple and linear weighted Cohen's kappa (k) coefficients.

RESULTS: Inter-reader concordance on CT for opacity presence, opacity extent, opacity distribution, and presence of subpleural lines and reticulation was 99%, 78%, 97%, 99%, and 94% (k 0.96, 0.86, 0.94, 0.97, 0.89), respectively. Inter-reader concordance on MR, among all 106 exams, for opacity presence, opacity extent, opacity distribution, and presence of subpleural lines and reticulation was 85%, 48%, 70%, 86%, and 76% (k 0.57, 0.32, 0.46, 0.47, 0.37), respectively. Inter-modality agreement between CT and MRI for opacity presence, opacity extent, opacity distribution, and presence subpleural lines and reticulation was 86%, 52%, 79%, 93%, and 76% (k 0.43, 0.63, 0.65, 0.80, 0.52).

CONCLUSION: Low-field 0.55 T non-contrast MRI demonstrates fair to moderate inter-reader concordance, and moderate to substantial inter-modality agreement with CT, for detection and characterization of groundglass and fibrosis-like opacities.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Azour, Condos, Keerthivasan, et al. Low-field 0.55 T MRI for assessment of pulmonary groundglass and fibrosis-like opacities: Inter-reader and inter-modality concordance. Eur J Radiol. 2022. PMID: 36099832. doi:10.1016/j.ejrad.2022.110515

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。