文献速递甲状腺与浅表头颈MR

专用表面线圈优化甲状腺扩散加权成像:FOCUS-DWI与常规DWI对比

Optimising diffusion-weighted imaging of the thyroid gland using dedicated surface coil.
PubMed 文献 · Clin Radiol · 2022-09-09

前瞻性纳入32名健康志愿者,在3 T MRI下使用甲状腺专用表面线圈比较FOCUS-DWI与常规DWI。FOCUS-DWI在整体图像质量、伪影、锐利度和几何变形上定性评分显著更优,但SNR和CNR显著更低,ADC值显著更高。两种序列各有优势,可按不同目的选择。

要点

  • FOCUS-DWI定性图像质量、伪影、锐利度和几何变形均显著优于常规DWI。
  • FOCUS-DWI的SNR和CNR显著低于常规DWI,ADC值显著更高。
  • 两种序列各有优势,临床可根据目的选择使用。

关键影像表现/征象

  • FOCUS-DWI在整体图像质量、伪影、锐利度和几何变形方面的定性评分显著优于常规DWI(均p<0.05)。
  • FOCUS-DWI的SNR显著低于常规DWI(p<0.001)。
  • FOCUS-DWI的CNR显著低于常规DWI(p=0.012)。
  • FOCUS-DWI的ADC值显著高于常规DWI(p<0.001)。

诊断标准与关键数值

  • 定性图像质量评估采用五点Likert量表,评估整体图像质量、伪影、锐利度和几何变形。
  • 两名评估者间一致性:FOCUS-DWI的κ=0.714-0.778(好),常规DWI的κ=0.525-0.672(中等至好)。

临床应用与阅片要点

  • FOCUS-DWI可减少甲状腺DWI的伪影和几何变形,适合需要优质形态学显示的场景。
  • 常规DWI SNR和CNR更高,适合需要高信噪比定量分析的场景。
  • FOCUS-DWI的ADC值显著高于常规DWI,解读ADC时需注意序列差异,避免直接跨序列比较。

局限性

  • 研究对象为健康志愿者,未纳入甲状腺病变患者。
  • 单中心前瞻性研究,样本量32例。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

AIM: To assess the feasibility of applying field-of-view (FOV) optimised and constrained undistorted single-shot (FOCUS) diffusion-weighted imaging (DWI) in the thyroid gland by comparing its image quality with conventional DWI (C-DWI) qualitatively and quantitatively using a dedicated surface coil exclusively designed for the thyroid gland at 3 T magnetic resonance imaging (MRI).

MATERIALS AND METHODS: In this prospective study, 32 healthy volunteers who had undergone 3 T the thyroid gland MRI with FOCUS-DWI and C-DWI were enrolled. Two independent reviewers assessed the overall image quality, artefacts, sharpness, and geometric distortion based on a five-point Likert scale. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and apparent diffusion coefficient (ADC) were quantified for both sequences. Interobserver agreement, qualitative scores, and quantitative parameters were compared between two sequences.

RESULTS: Agreement between the two readers was good for FOCUS-DWI (κ = 0.714-0.778) and moderate to good for C-DWI (κ = 0.525-0.672) in qualitative image quality assessment. Qualitatively, image quality (overall image quality, artefacts, sharpness, and geometric distortion) was significantly better in FOCUS-DWI than that in the C-DWI (all p<0.05); however, quantitatively, FOCUS-DWI had significantly lower SNRs (p<0.001) and CNRs (p=0.012) compared with C-DWI. The ADC value on FOCUS-DWI was significantly higher than that on C-DWI (p<0.001).

CONCLUSION: FOCUS-DWI depicted the thyroid gland with significantly better image quality qualitatively and less ghost artefacts, but had significantly lower SNR and CNR quantitatively, compared with C-DWI, suggesting that both DWI sequences have advantages and could be chosen for different purposes.

来源:Clin Radiol,查看原文。版权归原作者所有。

引用

  1. Wang, Ren, Zhu, et al. Optimising diffusion-weighted imaging of the thyroid gland using dedicated surface coil. Clin Radiol. 2022. PMID: 36096939. doi:10.1016/j.crad.2022.07.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。