文献速递泌尿生殖腹部MR

基于mp-MRI影像组学与机器学习的前列腺癌分类:组织学共配准验证

Prostate cancer classification using radiomics and machine learning on mp-MRI validated using co-registered histology.
PubMed 文献 · Eur J Radiol · 2022-08-19

本研究将临床显著前列腺癌的组织学区域通过已验证的配准算法映射到mp-MRI,并采用形状和大小匹配的非癌区域采样以消除偏倚。5特征朴素贝叶斯分类器在留一患者交叉验证中AUC为0.80;仅外周带训练的模型性能(AUC 0.75)低于中央腺体(AUC 0.95)。类间面积不匹配增加会使分类器AUC中位数趋于偏高。

要点

  • 基于mp-MRI影像组学的机器学习模型可区分前列腺癌与非癌组织,验证AUC为0.80。
  • 外周带模型性能低于中央腺体,阅片时需注意不同带区的诊断差异。
  • 类间面积不匹配可正向偏倚AUC,评估模型时应关注采样偏倚。

诊断标准与关键数值

  • 5特征朴素贝叶斯分类器在留一患者交叉验证中AUC为0.80。
  • 仅外周带训练和测试的模型AUC为0.75,仅中央腺体训练和测试的模型AUC为0.95。
  • 分类器对前列腺癌与非癌病变间的形状差异不变(AUC: 0.82 vs 0.82)。

局限性

  • 原文未明确报告样本量、中心数及具体设备/序列信息。
  • 研究设计本身可能存在单中心、回顾性等局限,原文未详细说明。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

BACKGROUND: Multi-parametric magnetic resonance imaging (mp-MRI) is emerging as a useful tool for prostate cancer (PCa) detection but currently has unaddressed limitations. Computer aided diagnosis (CAD) systems have been developed to address these needs, but many approaches used to generate and validate the models have inherent biases.

METHOD: All clinically significant PCa on histology was mapped to mp-MRI using a previously validated registration algorithm. Shape and size matched non-PCa regions were selected using a proposed sampling algorithm to eliminate biases towards shape and size. Further analysis was performed to assess biases regarding inter-zonal variability.

RESULTS: A 5-feature Naïve-Bayes classifier produced an area under the receiver operating characteristic curve (AUC) of 0.80 validated using leave-one-patient-out cross-validation. As mean inter-class area mismatch increased, median AUC trended towards positively biasing classifiers to producing higher AUCs. Classifiers were invariant to differences in shape between PCa and non-PCa lesions (AUC: 0.82 vs 0.82). Performance for models trained and tested only in the peripheral zone was found to be lower than in the central gland (AUC: 0.75 vs 0.95).

CONCLUSION: We developed a radiomics based machine learning system to classify PCa vs non-PCa tissue on mp-MRI validated on accurately co-registered mid-gland histology with a measured target registration error. Potential biases involved in model development were interrogated to provide considerations for future work in this area.

来源:Eur J Radiol,查看原文。版权归原作者所有。

引用

  1. Alfano, Bauman, Gomez, et al. Prostate cancer classification using radiomics and machine learning on mp-MRI validated using co-registered histology. Eur J Radiol. 2022. PMID: 36095953. doi:10.1016/j.ejrad.2022.110494

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。