非增强CT血肿标志物预测CT灌注动态点征及其与血肿扩大和预后的关联
多因素分析显示不均匀密度是唯一与动态点征独立相关的NCCT标志物(OR 58.61),动态点征预测血肿扩大(OR 36.6),点征与低密度共定位预测院内死亡(OR 6.17)。
要点
- 不均匀密度是与CT灌注动态点征独立相关的最强NCCT血肿标志物。
- 动态点征对血肿扩大的预测价值强于NCCT血肿标志物。
- 点征与低密度共定位提示院内死亡风险增高。
关键影像表现/征象
- 不均匀密度是唯一在多因素分析中与动态点征独立相关的NCCT血肿标志物。
- 所有存在点征的患者均可见漩涡征。
- 点征与低密度共定位与院内死亡显著相关。
诊断标准与关键数值
- 不均匀密度预测动态点征:OR 58.61(95%CI 9.13-376.05),P<0.001。
- 动态点征预测血肿扩大:OR 36.6(95%CI 2.51-534.2),P=0.008。
- 点征与低密度共定位预测院内死亡:OR 6.17(95%CI 1.09-34.78),P=0.039。
临床应用与阅片要点
- 阅片时关注NCCT血肿不均匀密度和漩涡征,提示可能存在动态点征。
- 对存在动态点征者应警惕血肿扩大,及时复查CT。
- 点征与低密度共定位者需关注院内死亡风险。
局限性
- 单中心回顾性研究,结论外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
PURPOSE: To assess the association between non-contrast computed tomography (NCCT) hematoma markers and the dynamic spot sign on computed tomography perfusion (CTP), and their associations with hematoma expansion, clinical outcome, and in-hospital mortality.
METHODS: Patients who presented with intracerebral hemorrhage (ICH) to a stroke center over an 18-month period and underwent baseline NCCT and CTP, and a follow-up NCCT within 24 h after the baseline scan were included. The initial and follow-up hematoma volumes were calculated. Two raters independently assessed the baseline NCCT for hematoma markers and concurrently assessed the CTP for the dynamic spot sign. Univariate and multivariate logistic regression analyses were performed to assess the association between the hematoma markers and the dynamic spot sign, adjusting for known ICH expansion predictors.
RESULTS: Eighty-five patients were included in our study and 55 patients were suitable for expansion analysis. Heterogeneous density was the only NCCT hematoma marker to be associated with the dynamic spot sign after multivariate analysis (odds ratio, 58.61; 95% confidence interval, 9.13-376.05; P < 0.001). The dynamic spot sign was present in 22 patients (26%) and significantly predicted hematoma expansion (odds ratio, 36.6; 95% confidence interval, 2.51-534.2; P = 0.008). All patients with a spot sign had a swirl sign. A co-located hypodensity and spot sign was significantly associated with in-hospital mortality (odds ratio, 6.17; 95% confidence interval, 1.09-34.78; P = 0.039).
CONCLUSION: Heterogeneous density and swirl sign are associated with the dynamic spot sign. The dynamic spot sign is a stronger predictor than NCCT hematoma markers of significant hematoma expansion. A co-located spot sign and hypodensity predicts in-hospital mortality.
引用
- Truong, Metcalfe, Ovenden, et al. Intracerebral hemorrhage markers on non-contrast computed tomography as predictors of the dynamic spot sign on CT perfusion and associations with hematoma expansion and outcome. Neuroradiology. 2022. PMID: 36076088. doi:10.1007/s00234-022-03032-6
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。