压缩感知T2螺旋桨采集用于快速运动稳健前列腺MRI:与传统采集对比
前瞻性纳入29例临床怀疑前列腺癌的男性,在3T行前列腺MRI,对比压缩感知T2螺旋桨序列(T2 CS)与传统T2螺旋桨序列(T2 conv)。T2 CS在轴位和矢状位均缩短采集时间约24%-26%,并提升图像质量、信噪比和对比噪声比,PI-RADS评分一致。
要点
- T2 CS序列轴位和矢状位采集时间分别缩短26%和24%,轴位171秒 vs 232秒。
- 轴位T2 CS伪影更少、锐利度、包膜 delineation 和整体图像质量更优。
- 矢状位T2 CS在伪影、锐利度、病灶 conspicuity 和整体图像质量更优。
关键影像表现/征象
- 轴位T2 CS较T2 conv伪影更少(4 [4-4.5] vs 4 [3-4],P<0.001),图像锐利度更好(4 [4-4.5] vs 3 [3-3.5],P<0.001)。
- 轴位T2 CS包膜 delineation 更好(4 [3-4] vs 3 [3-3.5],P<0.001),整体图像质量更高(4 [4-4] vs 4 [3-4],P<0.001)。
- 矢状位T2 CS在伪影(4 [4-4] vs 3 [3-4],P<0.001)、锐利度(4 [4-5] vs 4 [3-4],P<0.001)、病灶 conspicuity(4 [4-4] vs 4 [3-4],P=0.002)和整体图像质量(4 [4-4] vs 4 [3-4],P=0.002)均优于T2 conv。
- 轴位T2 CS的表观信噪比更高(52.2±9.7 vs 22.8±3.6,P<0.001),表观对比噪声比更高(44.0±9.6 vs 18.6±3.7,P≤0.001)。
诊断标准与关键数值
- 图像质量采用5分Likert量表(1=不可诊断,5=优秀),由2名盲法放射科医师评估。
- 轴位T2 CS采集时间171秒 vs T2 conv 232秒(P<0.001),缩短26%;矢状位缩短24%。
- 观察者内ICC为0.92,观察者间ICC为0.86。
- PI-RADS评分在两序列间所有受试者一致。
临床应用与阅片要点
- 在日常前列腺MRI中,可采用T2 CS序列替代传统T2螺旋桨序列以缩短扫描时间并提高图像质量。
- T2 CS在轴位和矢状位均能提供更好的包膜 delineation 和病灶 conspicuity,有助于前列腺癌定位和分期。
- 两序列PI-RADS评分一致,提示T2 CS不影响基于PI-RADS的病变评估。
局限性
- 单中心前瞻性研究,样本量较小(29例)。
- 仅纳入临床怀疑前列腺癌的男性,未包括其他前列腺疾病人群。
- 未报告病理对照或诊断准确性数据。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: The aim of this study was to compare a new compressed sensing (CS) method for T2-weighted propeller acquisitions (T2 CS ) with conventional T2-weighted propeller sequences (T2 conv ) in terms of achieving a higher image quality, while reducing the acquisition time.
MATERIALS AND METHODS: Male participants with a clinical suspicion of prostate cancer were prospectively enrolled and underwent prostate magnetic resonance imaging at 3 T. Axial and sagittal images of the T2 conv sequence and the T2 CS sequence were acquired. Sequences were qualitatively assessed by 2 blinded radiologists concerning artifacts, image-sharpness, lesion conspicuity, capsule delineation, and overall image quality using 5-point Likert items ranging from 1 (nondiagnostic) to 5 (excellent). The apparent signal-to-noise ratio and apparent contrast-to-noise ratio were evaluated. PI-RADS scores were assessed for both sequences. Statistical analysis was performed by using Wilcoxon signed rank test and paired samples t test. Intrarater and interrater reliability of qualitative image evaluation was assessed using intraclass correlation coefficient (ICC) estimates.
RESULTS: A total of 29 male participants were included (mean age, 66 ± 8 years). The acquisition time of the T2 CS sequence was respectively 26% (axial plane) and 24% (sagittal plane) shorter compared with the T2 conv sequence (eg, axial: 171 vs 232 seconds; P < 0.001). In the axial plane, the T2 CS sequence had fewer artifacts (4 [4-4.5] vs 4 [3-4]; P < 0.001), better image-sharpness (4 [4-4.5] vs 3 [3-3.5]; P < 0.001), better capsule delineation (4 [3-4] vs 3 [3-3.5]; P < 0.001), and better overall image quality (4 [4-4] vs 4 [3-4]; P < 0.001) compared with the T2 conv sequence. The ratings of lesion conspicuity were similar (4 [4-4] vs 4 [3-4]; P = 0.166). In the sagittal plane, the T2 CS sequence outperformed the T2 conv sequence in the categories artifacts (4 [4-4] vs 3 [3-4]; P < 0.001), image sharpness (4 [4-5] vs 4 [3-4]; P < 0.001), lesion conspicuity (4 [4-4] vs 4 [3-4]; P = 0.002), and overall image quality (4 [4-4] vs 4 [3-4]; P = 0.002). Capsule delineation was similar between both sequences (3 [3-4] vs 3 [3-3]; P = 0.07). Intraobserver and interobserver reliability for qualitative scoring were good (ICC intra: 0.92; ICC inter: 0.86). Quantitative analysis revealed a higher apparent signal-to-noise ratio (eg, axial: 52.2 ± 9.7 vs 22.8 ± 3.6; P < 0.001) and a higher apparent contrast-to-noise ratio (eg, axial: 44.0 ± 9.6 vs 18.6 ± 3.7; P ≤ 0.001) of the T2 CS sequence. PI-RADS scores were the same for both sequences in all participants.
CONCLUSIONS: CS-accelerated T2-weighted propeller acquisition had a superior image quality compared with conventional T2-weighted propeller sequences while significantly reducing the acquisition time.
引用
- Bischoff, Katemann, Isaak, et al. T2 Turbo Spin Echo With Compressed Sensing and Propeller Acquisition (Sampling k-Space by Utilizing Rotating Blades) for Fast and Motion Robust Prostate MRI: Comparison With Conventional Acquisition. Invest Radiol. 2022. PMID: 36070533. doi:10.1097/RLI.0000000000000923
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。