Pilot Tone触发MRI与ECG触发在心脏功能、运动及结构定量评估中的一致性研究
结果显示两种触发方法在容积、射血分数、T1/T2值及纵向应变等指标上无显著差异,组内相关系数主要介于0.73至0.98,变异系数为1.4%至22.6%,表明PT触发与ECG触发具有良好一致性,有望作为心血管成像中ECG门控的备份方案。
要点
- PT触发与ECG触发测量的心功能及结构指标具有良好一致性,ICC主要0.73-0.98。
- 两种触发方式在EDV、ESV、SV、EF、左室质量、T1/T2值及纵向应变上无显著差异。
- PT触发可作为ECG门控的潜在备份方案,尤其适用于ECG信号不佳时。
英文原文(摘要)· 点击展开
OBJECTIVE: The aim of this study was to test the hypothesis that there are good agreements between cardiac functional and structural indices derived from magnetic resonance imaging (MRI) sequences triggered with pilot tone (PT) and electrocardiogram (ECG).
MATERIALS AND METHODS: Sixteen healthy volunteers (11 male, age 21-76 years) underwent a cardiac MRI scan. Cine MRI, T1, and T2 mapping were acquired by using PT and ECG triggering. Quantitative measurements, including left and right ventricular end-diastolic volume, end-systolic volume, stroke volume, ejection fraction, longitudinal strain, left ventricular T1 and T2 values, left and right atrial longitudinal strain, and maximal/minimal volumes, were measured. The interclass correlation coefficient, coefficient of variation, and Bland-Altman plots were used to evaluate the agreements between measurements derived by MRI sequences triggered with 2 methods.
RESULTS: There were no significant differences among end-diastolic volume, end-systolic volume, stroke volume, ejection fraction, left ventricle mass, T1 and T2 values, or longitudinal strains acquired using PT and ECG. There were good agreements and low variations between the levels of these indices acquired with PT and ECG. Interclass correlation coefficients mainly ranged from 0.73 to 0.98. The coefficients of variation ranged from 1.4% to 22.6%.
CONCLUSIONS: Pilot tone-triggered MRI provides comparable measurements of cardiac function, motion, and structure as ECG-triggered MRI. Pilot tone has the potential to become a backup of ECG gating in cardiovascular imaging.
引用
- Lin, Sarnari, Speier, et al. Pilot Tone-Triggered MRI for Quantitative Assessment of Cardiac Function, Motion, and Structure. Invest Radiol. 2022. PMID: 36070525. doi:10.1097/RLI.0000000000000922
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。