光子计数探测器CT联合深度学习降噪检测多发性骨髓瘤
本研究前瞻性纳入27例受试者,比较光子计数探测器(PCD)CT与能量积分探测器(EID)CT在全身低剂量扫描中显示多发性骨髓瘤病变的差异。结果显示,PCD CT在观察溶骨性病变、髓内病变、脂肪化及病理性骨折方面均优于EID CT,0.6mm薄层结合卷积神经网络降噪进一步提高了病变检出。
要点
- PCD CT超高分分辨率模式可提高多发性骨髓瘤溶骨性病变的可见性
- 0.6mm薄层PCD CT联合深度学习降噪能检出更多溶骨性病变
- 与EID CT相比,PCD CT在匹配辐射剂量下改善图像质量
关键影像表现/征象
- PCD CT在观察溶骨性病变、髓内病变、脂肪化及病理性骨折方面较EID CT有改善(所有比较P < .05)。
- 0.6mm PCD CT图像经卷积神经网络降噪后,在27例参与者中的21例检测到一个或多个溶骨性病变,优于2mm EID CT图像(P < .001)。
诊断标准与关键数值
- 两名放射科医生采用五点Likert量表对PCD CT图像相对于EID CT进行评分,以检测反映多发性骨髓瘤的征象。
- 对匹配重建序列的评分对扫描仪类型设盲。
临床应用与阅片要点
- 在全身低剂量CT中,使用PCD CT超高分分辨率模式联合深度学习降噪可提高多发性骨髓瘤病变的检出和显示。
- 阅片时应关注溶骨性病变、髓内病变、脂肪化及病理性骨折等征象。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
Background Photon-counting detector (PCD) CT and deep learning noise reduction may improve spatial resolution at lower radiation doses compared with energy-integrating detector (EID) CT. Purpose To demonstrate the diagnostic impact of improved spatial resolution in whole-body low-dose CT scans for viewing multiple myeloma by using PCD CT with deep learning denoising compared with conventional EID CT. Materials and Methods Between April and July 2021, adult participants who underwent a whole-body EID CT scan were prospectively enrolled and scanned with a PCD CT system in ultra-high-resolution mode at matched radiation dose (8 mSv for an average adult) at an academic medical center. EID CT and PCD CT images were reconstructed with Br44 and Br64 kernels at 2-mm section thickness. PCD CT images were also reconstructed with Br44 and Br76 kernels at 0.6-mm section thickness. The thinner PCD CT images were denoised by using a convolutional neural network. Image quality was objectively quantified in two phantoms and a randomly selected subset of participants (10 participants; median age, 63.5 years; five men). Two radiologists scored PCD CT images relative to EID CT by using a five-point Likert scale to detect findings reflecting multiple myeloma. The scoring for the matched reconstruction series was blinded to scanner type. Reader-averaged scores were tested with the null hypothesis of equivalent visualization between EID and PCD. Results Twenty-seven participants (median age, 68 years; IQR, 61-72 years; 16 men) were included. The blinded assessment of 2-mm images demonstrated improvement in viewing lytic lesions, intramedullary lesions, fatty metamorphosis, and pathologic fractures for PCD CT versus EID CT (P < .05 for all comparisons). The 0.6-mm PCD CT images with convolutional neural network denoising also demonstrated improvement in viewing all four pathologic abnormalities and detected one or more lytic lesions in 21 of 27 participants compared with the 2-mm EID CT images (P < .001). Conclusion Ultra-high-resolution photon-counting detector CT improved the visibility of multiple myeloma lesions relative to energy-integrating detector CT. © RSNA, 2022 Online supplemental material is available for this article.
引用
- Baffour, Huber, Ferrero, et al. Photon-counting Detector CT with Deep Learning Noise Reduction to Detect Multiple Myeloma. Radiology. 2022. PMID: 36066364. doi:10.1148/radiol.220311
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。