文献速递儿科影像腹部US

儿科急诊三维虚拟腹部远程超声与标准超声检查的可靠性比较

Reliability of 3-D Virtual Abdominal Tele-ultrasonography in Pediatric Emergency: Comparison with Standard-of-Care Ultrasound Examination.
PubMed 文献 · Ultrasound Med Biol · 2022-08-30

本研究前瞻性纳入103例因腹痛行超声检查的儿童,评估三维虚拟腹部远程超声的可靠性。远程图像由高年资和住院医师盲法判读,与标准超声相比敏感度分别为86%和84%,特异度95%和92%,观察者间κ为0.84。三维远程超声在儿科急诊中具有应用前景。

要点

  • 三维远程腹部超声与标准超声诊断一致性高(观察者间κ=0.84)。
  • 高年资医师远程判读敏感度86%、特异度95%,住院医师分别为84%、92%。
  • 超过95%的儿童、家长及操作者接受三维图像采集,84%图像质量良好至优秀。

诊断标准与关键数值

  • 高年资医师远程与标准超声比较:敏感度86%,特异度95%,阳性预测值92%,阴性预测值92%,Cohen's κ=0.82。
  • 住院医师远程与标准超声比较:敏感度84%,特异度92%,阳性预测值86%,阴性预测值91%,Cohen's κ=0.71。
  • 两名判读者间Cohen's κ=0.84。
  • 标准腹部检查与三维远程超声重建图像在病理病例定量变量上的组内相关系数为0.99(置信区间0.98-0.99)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Ultrasound is currently recommended as the first-line examination for abdominal symptoms in children. However, a pediatric radiologist is not always available on site, especially during on-call duty. This study was aimed at evaluating the reliability of an innovative 3-D virtual abdominal tele-ultrasonography in this context. A prospective study was conducted between December 2020 and May 2021 that recruited 103 children undergoing ultrasound for abdominal pain. Trauma cases were excluded. Four tridimensional acquisitions were performed with a Smart Sensor 3D device (Canon Medical Systems, Otawara, Japan). Each tele-ultrasonography was secondarily blindly reviewed by two radiologists (one senior and one resident) with Fusion software (Canon Medical Systems). Acceptance and quality of the acquisitions were evaluated on a Likert scale. Inter-rater reliability was quantified using Cohen's κ coefficient and intraclass correlation coefficient. The ultrasound examination was normal in 66 cases (64%), abnormal in 36 cases (35%) and inconclusive in 1 case (1%). The acquisitions were obtained without objections from the children, their parents or the operators in more than 95% of cases. The quality of the acquisitions was considered good to excellent in 84% and 70% of cases. The sensitivity of the senior radiologist and the resident was 86% and 84%, respectively; specificity was 95% and 92%, positive predictive value 92% and 86% and negative predictive value 92 and 91% when comparing the conclusions of the standard and the tele-ultrasound examinations. Cohen's κ coefficients of the diagnosis obtained with the standard and the tele-ultrasound examinations were 0.82 and 0.71, respectively. The inter-rater Cohen's κ coefficient was 0.84. The intraclass correlation coefficient between the standard abdominal examination and the 3-D tele-ultrasound reformatted images for the following quantitative variables on pathological cases was 0.99 (confidence interval: 0.98-0.99). Virtual abdominal tele-ultrasonography is a promising method in pediatric emergencies.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Morel, Hellec, Fievet, et al. Reliability of 3-D Virtual Abdominal Tele-ultrasonography in Pediatric Emergency: Comparison with Standard-of-Care Ultrasound Examination. Ultrasound Med Biol. 2022. PMID: 36055859. doi:10.1016/j.ultrasmedbio.2022.07.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。