文献速递心血管US

开发中心肌梗死区内滞留全氟丙烷微滴的声学检测

Acoustic Detection of Retained Perfluoropropane Droplets Within the Developing Myocardial Infarct Zone.
PubMed 文献 · Ultrasound Med Biol · 2022-08-30

本研究通过超高速显微成像和体外流动实验确定多脉冲序列比单脉冲谐波成像具有更低的心肌指数激活阈值,并在9只大鼠和10只猪的左前降支缺血模型中验证,静脉注射全氟丙烷微滴后3分钟,多脉冲基波非线性成像可在发育瘢痕区产生选择性对比增强。

要点

  • 多脉冲基波非线性成像比单脉冲谐波成像具有更低的心肌指数激活阈值。
  • 静脉注射全氟丙烷微滴后3分钟,发育瘢痕区内微滴存在量高于远隔区域。
  • 经胸高机械指数脉冲结合基波非线性成像可选择性增强发育瘢痕区。

关键影像表现/征象

  • 超高速显微成像显示多脉冲序列的心肌指数激活阈值低于单脉冲序列。
  • 两种脉冲序列的声学激活均在心肌指数≥0.4且低于惯性空化阈值时观察到。
  • 大鼠中,共聚焦显微镜和系列声学激活成像检测到静脉注射后3分钟发育瘢痕区内微滴存在量高于远隔区域。
  • 猪中,静脉注射后3分钟经胸高机械指数脉冲结合基波非线性成像导致发育瘢痕区内选择性对比增强。

诊断标准与关键数值

  • 声学激活在心肌指数≥0.4且低于惯性空化阈值时观察到,适用于两种脉冲序列。

临床应用与阅片要点

  • 利用多脉冲基波非线性成像和心肌指数≥0.4的脉冲序列可优化经胸超声对发育瘢痕区的显示。
  • 静脉注射全氟丙烷微滴后3分钟是检测发育瘢痕区内微滴滞留的适宜时间点。
  • 需注意声学激活应低于惯性空化阈值以避免组织损伤。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Perfluoropropane droplets (PDs) cross endothelial barriers and can be acoustically activated for selective myocardial extravascular enhancement following intravenous injection (IVI). Our objective was to determine how to optimally activate extravascular PDs for transthoracic ultrasound-enhanced delineation of a developing scar zone (DSZ). Ultrafast-frame-rate microscopy was conducted to determine the effect of pulse sequence on the threshold of bubble formation from PDs. In vitro studies were subsequently performed at different flow rates to determine acoustic activation and inertial cavitation thresholds for a PD infusion using multipulse fundamental non-linear or single-pulse harmonic imaging. IVIs of PDs were given in 9 rats and 10 pigs following prolonged left anterior descending ischemia to detect and quantify PD kinetics within the DSZ. A multipulse sequence had a lower myocardial index threshold for acoustic activation by ultrafast-frame-rate microscopy. Acoustic activation was observed at a myocardial index ≥0.4 below the inertial cavitation threshold for both pulse sequences. In rats, confocal microscopy and serial acoustic activation imaging detected higher droplet presence (relative to remote regions) within the DSZ at 3 min post-IVI. Transthoracic high-mechanical-index impulses with fundamental non-linear imaging in pigs at this time post-IVI resulted in selective contrast enhancement within the DSZ.

来源:Ultrasound Med Biol,查看原文。版权归原作者所有。

引用

  1. Zeng, Chen, Lof, et al. Acoustic Detection of Retained Perfluoropropane Droplets Within the Developing Myocardial Infarct Zone. Ultrasound Med Biol. 2022. PMID: 36050231. doi:10.1016/j.ultrasmedbio.2022.07.005

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。