腹主动脉及股动脉双能CT血管成像虚拟平扫与真实平扫图像对比
本研究纳入63例连续行腹主动脉及股动脉CT血管成像的患者,对比双能CT生成的虚拟平扫与真实平扫图像的CT值、噪声及主观质量。虚拟平扫CT值多高于真实平扫,噪声多低于真实平扫,主观评分3.68和3.63分(5分制),图像质量足以替代真实平扫诊断钙化病变。
要点
- 虚拟平扫图像质量足以替代真实平扫用于诊断钙化病变。
- 虚拟平扫CT值多高于真实平扫,噪声多低于真实平扫。
- 采用双能CT虚拟平扫可避免CT血管成像中不必要的辐射暴露。
关键影像表现/征象
- 虚拟平扫CT值多数高于真实平扫,仅读者2所测右股动脉例外。
- 真实平扫图像噪声多数高于虚拟平扫,仅读者1所测腹主动脉例外。
- 虚拟平扫主观评分按5分制分别为3.68和3.63分(读者1和读者2),提示诊断质量良好至优秀。
临床应用与阅片要点
- 虚拟平扫可替代真实平扫用于CT血管成像中钙化病变的诊断,减少患者辐射剂量。
- 阅片时注意虚拟平扫CT值可能高于真实平扫、噪声可能更低,需结合钙化减影伪影评估。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVES: To assess whether virtual non-contrast (VNC) computed tomography (CT) images acquired from dual-energy CT (DECT) have sufficient image quality to replace true non-contrast (TNC) CT images in CT angiography (CTAG).
METHODS: This study enrolled 63 consecutive patients who underwent a CTAG that included a single-energy non-contrast scan, followed by a post-contrast DECT scan. Comparison of attenuation and noise between TNC and VNC images was made by drawing circular regions of interest (ROI) on a picture archiving and communication system (PACS) workstation within the aortic lumen at the levels of the renal arteries, the aortic bifurcation and right femoral artery. Mean attenuation and image noise (one standard deviation) were registered in Hounsfield units (HU). The VNC images were subjectively evaluated for artifacts such as subtraction of calcifications or architectural distortion based on TNC image as a standard of reference.
RESULTS: Most attenuations of the VNCs were higher than TNC, except right femoral artery of reader 2. Most image noises of TNC were higher than VNC, except abdominal aorta in reader 1. In qualitative image analysis, mean scores of VNC according to the 5-point scale were 3.68 and 3.63 (reader 1 and reader 2, respectively) which mean good to excellent to diagnose.
CONCLUSION: HUs and VNC image noises are different from TNC images in CTAG. VNC images have sufficient image quality to replace TNC images in the diagnosis of calcific lesions.
ADVANCES IN KNOWLEDGE: VNC images acquired from DECT have image quality adequate to replace TNC images in the diagnosis of the calcific lesion on the CTAG. VNC images based on DECT can avoid excessive and unnecessary patient exposure to radiation during CTAG.
引用
- Lee, Park, Kim, et al. Virtual non-contrast images from dual-energy CT angiography of the abdominal aorta and femoral arteries: comparison with true non-contrast CT images. Br J Radiol. 2022. PMID: 36039820. doi:10.1259/bjr.20220378
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。