文献速递儿科影像技术与安全DR

新生儿X线摄影中防护推车对操作者散射辐射防护的体模研究

A phantom study of a protective trolley for neonatal radiographic imaging: new equipment to protect the operator from scatter radiation.
PubMed 文献 · Pediatr Radiol · 2022-08-26

本研究通过体模操作者测量标准新生儿胸部X线摄影时三个防护场景(防护推车、接触式个人防护装备、无防护)和三个距离下对辐射敏感器官的散射辐射剂量,发现短距离下使用防护推车时散射辐射表面剂量较个人防护装备和无防护均显著降低(所有辐射敏感器官P<0.05)。该新型防护推车为放射技师提供了一种非接触式防护工具。

要点

  • 短距离下防护推车可显著降低操作者辐射敏感器官的散射辐射表面剂量。
  • 防护推车为非接触式防护,避免个人防护装备共享问题。
  • 研究为体模实验,临床实际防护效果需进一步验证。

诊断标准与关键数值

  • 短距离下防护推车相比个人防护装备和无防护,所有辐射敏感器官的散射辐射表面剂量均显著降低(P<0.05)。

临床应用与阅片要点

  • 新生儿X线摄影时可考虑使用防护推车作为非接触式防护工具,减少操作者散射辐射暴露。
  • 注意防护推车的防护效果与距离相关,短距离下优势明显。

局限性

  • 研究为体模实验,非临床实际环境。
  • 未报告样本量、置信区间等详细统计信息。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

英文原文(摘要)· 点击展开

Chest radiography is commonly performed as a diagnostic tool of neonatal diseases. Contact-based radiation personal protective equipment (RPPE) has been widely used for radiation protection, but it does not provide full body protection and it is often shared between users, which has become a major concern during the coronavirus disease 2019 (COVID-19) pandemic. To address these issues, we developed a novel trolley to protect radiographers against X-ray radiation by reducing scatter radiation during neonatal radiographic examinations. We measured the scatter radiation doses from a standard neonatal chest radiograph to the radiosensitive organs using a phantom operator in three protection scenarios (trolley, radiation personal protective equipment [RPPE], no protection) and at three distances. The results showed that the scatter radiation surface doses were significantly reduced when using the trolley compared with RPPE and with no protection at a short distance (P<0.05 for both scenarios in all radiosensitive organs). The novel protective trolley provides a non-contact protective tool for radiographers against the hazard of scatter radiation during neonatal radiography examinations.

来源:Pediatr Radiol,查看原文。版权归原作者所有。

引用

  1. Wang, Xu, Chen, et al. A phantom study of a protective trolley for neonatal radiographic imaging: new equipment to protect the operator from scatter radiation. Pediatr Radiol. 2022. PMID: 36018348. doi:10.1007/s00247-022-05488-3

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。