基于卷积神经网络的颅内颅外动脉自动化形态学分析
本研究纳入67例受试者(47名健康志愿者和20例动脉粥样硬化患者)的DANTE-SPACE序列MR血管壁图像及TOF-MRA图像,开发基于CNN的自动化方法进行血管中心线追踪、管壁分割和形态学测量。自动分割与人工分割一致性良好,颅内动脉管腔和管壁Dice系数分别为0.90和0.78,颅外动脉分别为0.90和0.82;两种方法测量的最大管壁厚度和NWI无显著差异(p>0.05)。
要点
- CNN自动分割血管壁与人工分割一致性良好,颅内管壁Dice 0.78、颅外0.82。
- 自动测量的最大管壁厚度和NWI与人工测量无显著差异(p>0.05)。
- 斑块层面自动测量的NWI显著大于正常层面。
核心结论
- 基于CNN的自动化方法可实现颅内和颅外MR血管壁图像的自动分割与形态学定量,有望促进大规模动脉血管壁形态学定量分析。
研究设计与样本
- 方法学研究,纳入67例受试者(47名健康志愿者和20例动脉粥样硬化患者)的DANTE-SPACE序列MR血管壁图像及对应TOF-MRA图像,使用11,735层训练和验证、2,517层测试。
诊断标准与关键数值
- 自动分割与人工分割的Dice系数:颅内动脉管腔0.90、管壁0.78;颅外动脉管腔0.90、管壁0.82。
- 自动与人工测量的最大管壁厚度和NWI无显著差异(p>0.05)。
- 自动测量的斑块层面NWI显著大于正常层面。
临床应用与阅片要点
- 自动分割可用于颅内和颅外动脉血管壁的形态学定量,但自动测量的最大管壁厚度和NWI略大于人工测量。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
英文原文(摘要)· 点击展开
OBJECTIVE: To develop an automated method for 3D magnetic resonance (MR) vessel wall image analysis to facilitate morphologic quantification of intra- and extracranial arteries, including vessel centerline tracking, vessel straightening and reformation, vessel wall segmentation based on convoluted neural networks (CNNs), and morphological measurement.
METHODS: MR vessel wall images acquired using DANTE-SPACE sequences and corresponding time-of-flight-MRA images of 67 subjects (including 47 healthy volunteers and 20 patients with atherosclerosis) were included in this study. The centerline of the vessel was firstly extracted from the MRA images and copyed to the 3D MR vessel wall images through the registration relationship between the MRA images and the MR vessel wall images to extract, straighten, and reconstruct interested vessel segments into 2D slices. Then a complete CNN-based Unet-like method was used to automatically segment the vessel wall to obtain quantitative morphological measurements such as maximum wall thicknesses and normalized wall index (NWI).
RESULTS: The proposed automatic segmentation network was trained and validated with 11,735 slices and tested on 2517 slices. The method showed satisfactory agreement with manual segmentation method. The Dice coefficients of intracranial arteries were 0.90 for lumen and 0.78 for vessel wall, while the Dice coefficients of extracranial arteries were 0.90 for lumen and 0.82 for vessel wall. The maximum wall thickness and NWI obtained from the proposed automatic method were slightly larger than those obtained from the manual method for both intra- and extracranial arteries. However, there was no significant difference of the quantitative measurements between the two methods (p > 0.05). In addition, the automatically measured NWI of plaque slice was significantly larger than that of normal slice.
CONCLUSION: We propose an automatic analysis method of MR vessel wall images, which can realize automatic segmentation of intra- and extracranial vessel wall. It is expected to facilitate large-scale arterial vessel wall morphological quantification.
ADVANCES IN KNOWLEDGE: We have proposed an automatic method for analysis of intra- and extracranial MR vessel wall images simultaneously based on CNN, which can facilitate large-scale quantitative analyses of vessel walls.
引用
- Wan, Li, Zhang, et al. Automated morphologic analysis of intracranial and extracranial arteries using convolutional neural networks. Br J Radiol. 2022. PMID: 36018822. doi:10.1259/bjr.20210031
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。